Related Experiment Video
Updated: Feb 7, 2026

Design and Development of Aptamer–Gold Nanoparticle Based Colorimetric Assays for In-the-field Applications
Published on: June 23, 2016
Aptamer-functionalized AuNPs for the high-sensitivity colorimetric detection of melamine in milk samples
Xinran Hu1,2, Keke Chang2,3, Shun Wang2,3
1School of Biological Sciences, The University of Hong Kong, Hong Kong SAR, China.
Abstract:
Although aptamer-functionalized AuNPs technology exhibits great potential in analytical and biological chemistry, direct analysis of molecules at a low concentration using colorimetric assay remains challenging. The development of intuitive methods has attracted interest for promising detection of melamine in milk samples due to a demand for stable and understandable process. In this study, we propose a rapid and facile colorimetric measurement method of melamine combined aptamer-functionalized AuNPs in contaminated milk samples. To realize the high stability and the lower limit of detection, the aptamer-functionalized surface of AuNPs via a coordinated bond was used in combination with ultra-sonication. The kinetics of this colorimetric assay based on aptamer-functionalized AuNPs was analyzed to illustrate that the higher the concentration of melamine, the faster the aggregation of AuNPs induced. The sensitivity, selectivity, limit of detection and recovery rate were sufficiently validated to understand the measurement principle of melamine using aptamer-functionalized AuNPs. The calibration curve established by the absorption peak ratio (A640 /A520) was linear in the concentration range of 0~1μM of melamine in aqueous solutions with the correlation coefficient (R2) of 0.986 and the limit of detection (LOD) of 22 nM, whereas, the correlation coefficient (R2) of 0.998 and the LOD of 14.9 nM were achieved at the concentration of melamine below 0.5 μM in milk samples. The optimized performance of this colorimetric assay of melamine using aptamer-functionalized AuNPs in milk samples was obtained with 100 μL of 13 nm AuNPs solution, 40 μL of 1 μM (100 dilutions) aptamers and the pre-reaction time of 30 min. This simple colorimetric measurement of melamine using aptamer-functionalized AuNPs provides a promising target for various applications of the sample source with complex sample matrices.
Related Concept Videos
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Functional Groups
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Urine Studies II: Urine Culture and Sensitivity Test
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...

