Nanostructured electrochemical immunosensor for detection of serological alkaline phosphatase
Estefani P Simão1, Isaac A M Frías2, Cesar A S Andrade3
1Programa de Pós-Graduação em Ciências Biológicas, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil.
Abstract:
Alkaline phosphatase (ALP) is an enzyme that plays an important role in bone mineralization and skeletal growth. Variations in physiological levels of ALP have been correlated to diseases such as osteomalacia, Paget's disease and arterial calcifications. In this context, the integration of carbon nanotubes (CNT) within osteointegration implants has shown to increase ALP's mineralization activity in virtue of their surface chemistry and their morphological resemblance to collagen nanofibers. In this study we present the development and analytical application of an impedimetric immunosensor based in gold nanoparticle-decorated CNT, which characteristics are desirable in implantable biosensors. The device effectively detects ALP within blood serum, a complex biological fluid where most expressed proteins can be found. Robustness and high sensitivity were attained by immobilizing covalently anti-ALP antibody as a specific probe towards ALP. Cyclic voltammetry, electrochemical impedance spectroscopy and atomic force microscopy were used to characterize the sensor system throughout mounting steps and real sample testing. Impedimetric responses were adjusted to a theoretical electrical circuit and charge transfer resistance showed to be an adequate parameter to evaluate the biorecognition process of the analyte. Additionally, amperometrical current variation and changes in topography found over the surface after positive samples evidenced biorecognition. The final biosensor showed excellent performance with two linear ranges from 0.5 to 50 IU.L-1 and from 100 to 600 IU.L-1; limits of detection were calculated as 0.25 and 84.6 IU.L-1 respectively with a relative standard deviation lower than 5%. The device was found to be selective, avoiding protein c, a potential interferer occurring during inflammatory processes. The proposed strategy is promising for osteogenic applications where it can improve osteointegration implants by monitoring ALP activity.
Related Concept Videos
Protein Kinases and Phosphatases
Protein kinases
Many proteins in the cell are regulated by phosphorylation, the addition of a phosphate group. A family of enzymes called kinases...
Protein Kinases and Phosphatases
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Interfacial Electrochemical Methods: Overview
Electrochemical Gradient and Channel Proteins: An Overview
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...
Detection of Gross Error: The Q Test