Comparison of second- and third-generation immunoassays for detection of anti-cyclic citrullinated peptide antibodies
Misuk Ji1, Mina Hur2, Hee-Won Moon2
1a Department of Laboratory Medicine , Veterans Health Service (VHS) Medical Center , Seoul , Korea.
Abstract:
Anti-cyclic citrullinated peptide antibodies (anti-CCPs) are important diagnostic markers for rheumatoid arthritis (RA). We evaluated the analytical and clinical performance of the QUANTA Flash CCP3 (INOVA Diagnostics, USA), a fully automated third-generation anti-CCP assay, in comparison with three second-generation anti-CCP (CCP2) assays. A total of 300 sera (67 from RA patients, 64 from other rheumatic diseases, 43 from osteoarthritis [OA], and 126 from other conditions) were tested with QUANTA Flash CCP3, Kallestad Anti-CCP II (Bio-Rad, USA), Elecsys Anti-CCP (Roche Diagnostics GmbH, Germany), and ARCHITECT Anti-CCP (Abbott Diagnostics, USA). Within-run and total imprecision (% coefficient of variation) of the QUANTA Flash CCP3 were <6%, and its linearity was acceptable over the claimed range (4.0-2,749.7 chemiluminescent units). The frequency of anti-CCP was similar between QUANTA Flash CCP3 and the other CCP2 assays in the RA (67.2% vs. 62.7-70.1%), other rheumatic diseases (7.8% vs. 6.3%), and OA (2.3% vs. 0-2.3%) groups. The concordance rate between QUANTA Flash CCP3 and the other assays ranged from 96.3% to 97.7% (kappa from 0.87 to 0.92). For the diagnosis of RA, the sensitivity/specificity was 67.2%/95.7%, 62.7%/98.3%, 70.2%/96.6%, and 67.2%/97.9%, and the areas under the receiver operating characteristic curves were 0.851, 0.791, 0.853, and 0.867 for QUANTA Flash CCP3, Kallestad, Elecsys, and ARCHITECT assays, respectively. The performance of the QUANTA Flash CCP3 was satisfactory and comparable to that of the three CCP2 assays. This fully automated assay would be a practical and reasonable option in clinical laboratories.
More Related Videos
10:12Construction of Cyclic Cell-Penetrating Peptides for Enhanced Penetration of Biological Barriers
Published on: September 19, 2022
08:21Cell-Free Dot Blot as a Practical and Adaptable Immunoassay Platform for the Detection of Antibody Response in Human and Animal Sera
Published on: May 23, 2025
Related Concept Videos
Peptide Bonds
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Stereoisomerism of Cyclic Compounds
Voltammetric Techniques: Cyclic Voltammetry
Cyclic Processes And Isolated Systems
In the case of a non-isolated system, the change in the internal energy is zero only if the process is cyclic. A thermodynamic process is considered cyclic if the system undergoes a series of changes and returns to its initial state.
Consider a cyclic process that returns to its initial state, undergoing a four-step process. The heat transfer along each...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...