Circularly polarised fluorescence and phosphorescence calculations on organic molecules using the approximate

Chetana Badala Viswanatha1, Benjamin Helmich-Paris, Christof Hättig

  • 1Lehrstuhl für Theoretische Chemie, Ruhr Universität Bochum, D-44780, Bochum, Germany. BadalaViswanatha@rub.de Christof.Haettig@rub.de.

Related Concept Videos

Photoluminescence: Fluorescence and Phosphorescence01:23

Photoluminescence: Fluorescence and Phosphorescence

Photoluminescence is a process where a molecule absorbs light energy and re-emits it in the form of light. This phenomenon occurs when a substance absorbs photons, promoting its electrons to higher energy level excited states, followed by a relaxation process in which the electrons return to their original ground state energy levels and emit light. Photoluminescence is widely observed in various materials, including semiconductors, and organic and inorganic compounds.
A pair of electrons in a...
3.9K
Variables Affecting Phosphorescence and Fluorescence01:26

Variables Affecting Phosphorescence and Fluorescence

Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
1.5K
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
1.6K
Oxidation and Reduction of Organic Molecules01:19

Oxidation and Reduction of Organic Molecules

Energy production within a cell involves many coordinated chemical pathways. Most of these pathways are combinations of oxidation and reduction reactions, which occur at the same time. An oxidation reaction strips an electron from an atom in a compound, and the addition of this electron to another compound is a reduction reaction. Because oxidation and reduction usually occur together, these pairs of reactions are called redox reactions.
The removal of an electron from a molecule, results in a...
9.5K
Approximate Integration01:24

Approximate Integration

In many practical and theoretical contexts, the exact value of a definite integral may be inaccessible. This limitation typically arises when the antiderivative of a function is either unknown or cannot be expressed in a closed mathematical form. Alternatively, it can occur when a function is defined not by a formula but by a finite set of empirical data points, such as those collected during experiments. In these cases, approximate integration techniques provide a valuable solution.One of the...
56
Linearization and Approximation01:26

Linearization and Approximation

Linearization is a mathematical technique used to approximate complex, nonlinear functions with simpler linear models in the vicinity of a chosen reference point. The method is based on the idea that, although a function may be difficult to evaluate exactly, its behavior near a specific input value can often be closely approximated by the tangent line at that point. This approach is particularly useful when small deviations from a known value are involved.Consider the square root function, for...
68