[A New Calibrated Model of Coal Calorific Value Detection with LIBS]
Abstract:
A set of coal samples were used for laser-induced breakdown spectroscopy (LIBS) experiment to measure the coal calorific value. Traditional channel normalization method didn’t consider the physical / chemical mechanism of coal, which would limit the model in precision, accuracy and repeatability. Thus a new calibrated model based on the kinds of the effects of spectral deviation was proposed in this paper. The model selected 19 groups of coal samples, where the random 15 groups were used to establish quantitative analysis model of calorific value while the remaining four for inspection and evaluation. The model based on spectral deviation factors, and the transmission theory combined with the stark broadening formula was used to deduce the absorption effect mechanism and the deviation correction method under the condition of LIBS. The mutual interference between elements and the mechanism of matrix effect were being analyzed while K coefficient method was used to correct mutual interference between the elements in the LIBS. The establishment of numerical model with the electron density, the plasma temperature and the element concentration was used to deeply corrected spectrum deviation caused by matrix effect. Thus taking into consideration of the effect of self-absorption, interfere of inter-elements and matrix effect, the calibration model was established, while R2=0.967, RMSEP=0.49 MJ·kg-1, RMSE=0.45 MJ·kg-1, MRE=2.42%, ARE=1.64%, RSD=5.79% and RSDP=8.10%. Compared with the 0.405, 8.28 MJ·kg-1, 4.14 MJ·kg-1, 22.85%, 52.48%, 18.28% and 32.85% of traditional channel normalized-multiple linear regression method, it demonstrated that the precision and accuracy have been improved significantly and model has good application value.
More Related Videos
10:34Exploring the Radical Nature of a Carbon Surface by Electron Paramagnetic Resonance and a Calibrated Gas Flow
Published on: April 24, 2014
10:27A Uniaxial Compression Experiment with CO2-Bearing Coal Using a Visualized and Constant-Volume Gas-Solid Coupling Test System
Published on: June 12, 2019
Related Concept Videos
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Correlation Coefficient
Plotting and Calibrating the Root Locus
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Detection of Gross Error: The Q Test