Related Experiment Video
Updated: Feb 7, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Automated fastener (Core-Knot) versus manually tied knots in patients undergoing aortic valve replacement: Impact on
Dan Loberman1, Rephael Mohr, Paul A Pirundini
1Division of Cardiac Surgery, Brigham & Women's Hospital/Cape Cod Hospital, Harvard Medical School, Boston, MA Department of Epidemiology and Preventive Medicine, School of Public Health, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Abstract:
The Core-Knot device is an automatic fastener used mainly in minimally invasive heart valve surgery procedures, to facilitate knot tying. The purpose of this report is to compare ischemic time and outcomes of surgical aortic valve replacements (SAVRs) utilizing the Core-Knot device compared with manually tied knots.Between January, 2014 and December, 2016, 119 patients underwent SAVR in Cape Cod Hospital. We compared patient's characteristics, cross-clamp time, and outcomes of 75 patients who underwent SAVR using Core-Knot to those of 44 operated using manually tied knots.Patient characteristics were similar between groups. Patients in the Core-Knot group had higher preoperative aortic valve area and higher ejection fraction. The use of Core-Knot was associated with reduced aortic cross-clamp time (median 70 vs 84 minutes; P < .001). Patients undergoing SAVR using Core-Knot were less likely to have postoperative aortic regurgitation (P < .001). Early mortality, and also the rates of early adverse events (including all cardiac, neurologic, and renal complications), and the immediate postprocedure echo findings were similar in the 2 groups. In multivariate analysis, the use of Core-Knot was associated with reduced postoperative mean gradient across the aortic valve and reduced occurrence of postoperative aortic regurgitation. Older age and larger valve size were other predictors of reduced postoperative mean gradients.The use of an automatic fastener (Core-Knot) in surgical aortic valve replacement cases reduce aortic cross-clamp time and help eliminate postoperative paravalvular aortic regurgitation.
More Related Videos
Related Concept Videos
Crossing Over
The homologous pairs of sister chromosomes—one from the maternal and one from the paternal genome—then begin to align alongside each other lengthwise, matching corresponding DNA positions in a process...
Wood Fasteners
Nails are the most common fasteners, consisting of sharp-pointed metal pins that are driven into wood using a hammer or a mechanical nail gun. They come in a variety of diameters, heads, and lengths. Nailing techniques include...
The Nucleosome Core Particle
The paradox
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their main responsibility is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. While on the other hand, they must allow polymerase enzymes to access DNA...
Steel Fastening Techniques
Rivets are cylindrical steel fasteners with a specially designed head. During application, rivets are heated until white-hot and then inserted through pre-drilled holes in the steel sections. A pneumatic hammer is used to shape the exposed end into a second head, securing the sections together.
Bolting is another...
Cross-Sectional Research
Monohybrid Crosses

