Related Experiment Video
Updated: Feb 7, 2026

Characterizing Far-infrared Laser Emissions and the Measurement of Their Frequencies
Published on: December 18, 2015
Analyzing transient-evoked otoacoustic emissions by concentration of frequency and time
1Department of Mathematics and Department of Statistical Science, Duke University, 120 Science Drive, Durham, North Carolina 27705, USA.
Abstract:
The linear part of transient evoked otoacoustic emission (TEOAE) is thought to be generated via coherent reflection near the characteristic place of constituent wave components. Because of the tonotopic organization of the cochlea, high frequency emissions return earlier than low frequencies; however, due to the random nature of coherent reflection, the instantaneous frequency (IF) and amplitude envelope of TEOAEs both fluctuate. Multiple reflection components and synchronized spontaneous emissions can further make it difficult to extract the IF by linear transforms. This paper proposes to model TEOAEs as a sum of intrinsic mode-type functions and analyze it by a nonlinear-type time-frequency (T-F) analysis technique called concentration of frequency and time (ConceFT). When tested with synthetic otoacoustic emission signals with possibly multiple oscillatory components, the present method is able to produce clearly visualized traces of individual components on the T-F plane. Further, when the signal is noisy, the proposed method is compared with existing linear and bilinear methods in its accuracy for estimating the fluctuating IF. Results suggest that ConceFT outperforms the best of these methods in terms of optimal transport distance, reducing the error by 10% to 21% when the signal to noise ratio is 10 dB or below.
Related Concept Videos
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
The Integrated Rate Law: The Dependence of Concentration on Time
Emission Spectra
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...

