Related Experiment Video
Updated: Feb 7, 2026

Preparing Silica Aerogel Monoliths via a Rapid Supercritical Extraction Method
Published on: February 28, 2014
Critical considerations on load-to-failure test for monolithic zirconia molar crowns
Keisuke Nakamura1, Shuhei Ankyu2, Fritjof Nilsson3
1Department of Advanced Free Radical Science, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai 980 8575, Japan.
Abstract:
Application of monolithic zirconia crowns (MZCs) with reduced thickness to the molar region has been proposed, but potential complications have yet to be fully evaluated in laboratory tests. The present study aimed to develop a clinically relevant load-to-failure test in combination with fatigue treatments involving thermal and mechanical cycling (TC and MC) to evaluate the fracture resistance of molar MZCs. MZCs with a minimal thickness of 0.5 mm were bonded to dies made of resin-based composite (RBC), epoxy resin (EP), or polyoxymethylene-copolymer (POM-C). The samples were either untreated (UT) or subjected to TC (5-55 °C for 1 × 105 cycles) and MC (300 N for 2.4 × 106 cycles). The stress generated by TC and MC was simulated by finite element modeling. The load-to-failure test was performed using an inverse V-shaped two-plane indenter and was followed by fractographic analysis. The median values of fracture load for MZC/RBC and MZC/EP in the TC group were significantly lower than those in the UT group. MC also decreased the median value of fracture load for MZC/RBC significantly, but not that for MZC/EP and MZC/POM-C. Fractography revealed that the fracture started in the cervical area in all groups, which is similar to clinically failed crowns. The simulation confirmed stress concentration at the cervical area in both TC and MC groups. The present study suggests that the load-to-failure test using a two-plane indenter could induce clinically relevant fracture of MZCs, the vulnerability of the MZCs depends largely on the die material employed, and MZCs are more likely to be damaged by thermal fatigue than mechanical fatigue.
Related Concept Videos
Molar Mass
Crown Ethers
Design Consideration
The factor of safety is another key...
Critical Region, Critical Values and Significance Level
In hypothesis testing, a sample statistic is converted to a test statistic using z, t, or chi-square distribution. A critical region is an area under the curve in probability distributions demarcated by the critical value. When the test statistic falls in this region, it suggests that the null hypothesis must be rejected. As this region contains all those values of the...
Applications of the Ideal Gas Law: Molar Mass, Density, and Volume
Critical Values