Sequential Payload Release from Acoustically-Responsive Scaffolds Using Focused Ultrasound
Alexander Moncion1, Melissa Lin2, Oliver D Kripfgans3
1Applied Physics Program, University of Michigan, Ann Arbor, Michigan, USA; Department of Radiology, University of Michigan Health System, Ann Arbor, Michigan, USA.
Abstract:
Regenerative processes, such as angiogenesis and osteogenesis, often require multiple growth factors with distinct spatiotemporal patterns and expression sequences. Within tissue engineering, hydrogel scaffolds are commonly used for exogenous growth factor delivery. However, direct incorporation of growth factors within conventional hydrogels does not afford spatiotemporally controlled delivery because release is governed by passive mechanisms that cannot be actively controlled after the scaffold is implanted. We have developed acoustically-responsive scaffolds (ARSs), which are fibrin scaffolds doped with payload-containing, sonosensitive emulsions. Payload release from ARSs can be controlled non-invasively and on demand using focused, megahertz-range ultrasound. In the in vitro study described here, we developed and characterized ARSs that enable sequential release of two surrogate, fluorescent payloads using consecutive ultrasound exposures at different acoustic pressures. ARSs were generated with various combinations and volume fractions of perfluoropentane, perfluorohexane, and perfluoroheptane emulsions. Acoustic droplet vaporization and inertial cavitation thresholds correlated with the boiling point/molecular weight of the perfluorocarbon while payload release correlated inversely. Payload release was longitudinally measured and observed to follow a sigmoidal trend versus acoustic pressure. Perfluoropentane and perfluorohexane emulsions were stabilized when incorporated into ARSs with perfluoroheptane emulsion. These results highlight the potential of using ARSs for sequential, dual-payload release for tissue regeneration.
More Related Videos
08:39Multiplexing Focused Ultrasound Stimulation with Fluorescence Microscopy
Published on: January 7, 2019
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Energy-releasing Steps of Glycolysis
The first energy-releasing step—the 6th step of glycolysis...
Focusing of Light in the Eye
Coping Strategies: Problem Focused
For example, consider a student who struggles to understand their...
Responses to Drought and Flooding
Coping Strategies: Emotion Focused