Clusterin from human clinical tear samples: Positive correlation between tear concentration and Schirmer strip test
Valerie Yu1, Dhruva Bhattacharya2, Andrew Webster3
1MD Program, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, USA.
Purpose:
To investigate the relationship between tear concentration of the homeostatic protein clusterin (CLU) and dry eye signs and symptoms, and to characterize tear CLU protein.
Methods:
Two independent studies were conducted, one in Tucson (44 subjects), the other in Los Angeles (52 subjects). A cohort study design was employed to enroll patients without regard to dry eye diagnosis. Dry eye signs and symptoms were assessed using clinical tests. Tear samples were collected by Schirmer strip, and also by micropipette at slit lamp when possible. CLU from both sample types was quantified by immunoassay. The relationship between CLU concentration and clinical test scores was determined by Pearson's correlation coefficient (for individual eyes) and multiple linear regression analysis (including both eyes). CLU was also evaluated biochemically by western blotting.
Results:
In the Tucson cohort, a positive correlation was observed between tear CLU concentration and results of the Schirmer strip test, a measure of tear flow (p = 0.021 includes both eyes). This result was corroborated in the Los Angeles cohort (p = 0.013). The mean tear CLU concentration was 31 ± 14 μg/mL (n = 18 subjects, 33 eyes; range = 7-48 μg/mL). CLU from clinical tear samples appeared biochemically similar to CLU from a non-clinical tear sample and from blood plasma.
Conclusions:
Results support the hypothesis that an optimal concentration of tear CLU is important for ocular surface health, and that this drops below the effective threshold in dry eye. Tear CLU measurement might identify patients that could benefit from supplementation. Information about concentration will aid development of therapeutic dosage parameters.
Related Concept Videos
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Position-effect Variegation
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if: