Effect of simulated intraosseous sinusoidal pressure on NaOCl extrusion
Xue Cai1, Xiao-Yan Wang1, Filippo Santarcangelo2
1Department of Cariology and Endodontology, Peking University School and Hospital of Stomatology, Beijing, China.
Introduction:
The present study examined the effects of irrigant flow rate and simulated intraosseous sinusoidal pressure on the rate of NaOCl extrusion from the apical terminus of a faux root canal.
Methods:
An extrusion setup was designed to enable irrigant extrusion to be opposed by 30 mm Hg simulated intraosseous pressure. The faux canal apex was opposed by atmospheric + 30 mm Hg pressure (experimental) or atmospheric pressure only (control group). Using five irrigant delivery rates (15.6 8.0, 4.0, 3.4 or 3.0 mL/min), the extrusion rates of 2% NaOCl from the faux apex were measured in both groups (n = 16). Data were analysed with two-factor ANOVA and pairwise comparisons at α = 0.05. Correlation between NaOCl delivery rates and extrusion rates in both groups were analysed with the Pearson product-moment procedure.
Result:
Irrespective of the presence or absence of simulated sinusoidal pressure, NaOCl extrusion rates were positively-correlated with irrigant flow rates. For the factor "irrigant flow rates", significant differences in NaOCl extrusion rates were identified among all flow rates (p < 0.05), except for the pairwise comparison between 4.0 and 3.4 mL/min in the control. For all irrigant flow rates, NaOCl extrusion rate was significantly lower in the presence of 30 mm Hg simulated sinusoidal pressure than that obtained in the absence of opposing pressure (p < 0.05).
Conclusion:
In the presence of 30 mm Hg simulated intraosseous pressure, NaOCl delivered via a side-vented needle inserted to 1 mm short of working length may be prevented from extrusion when its flow rate is ≤ 3.0 mL/min.
Clinical Significance:
When opposed by intraosseous sinusoidal pressure, NaOCl delivered via a side-vented needle inserted to 1 mm short of working length may be prevented from extrusion when its flow rate is ≤ 3.0 mL/min.
Related Concept Videos
Sinusoidal Sources
In homes, the power supplies use sinusoidal sources to provide electricity. These sources generate a voltage that varies sinusoidally...
Exponential and Sinusoidal Signals
Graphical and Analytic Representation of Sinusoids
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...
Vapor Pressure
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Constant Pressure Calorimetry