Visually validated semi-automatic high-frequency oscillation detection aides the delineation of epileptogenic regions
Shennan Aibel Weiss1, Brent Berry2, Inna Chervoneva3
1Dept. of Neurology and Neuroscience, Thomas Jefferson University, Philadelphia, PA 19107, USA.
Objective:
To test the utility of a novel semi-automated method for detecting, validating, and quantifying high-frequency oscillations (HFOs): ripples (80-200 Hz) and fast ripples (200-600 Hz) in intra-operative electrocorticography (ECoG) recordings.
Methods:
Sixteen adult patients with temporal lobe epilepsy (TLE) had intra-operative ECoG recordings at the time of resection. The computer-annotated ECoG recordings were visually inspected and false positive detections were removed. We retrospectively determined the sensitivity, specificity, positive and negative predictive value (PPV/NPV) of HFO detections in unresected regions for determining post-operative seizure outcome.
Results:
Visual validation revealed that 2.81% of ripple and 43.68% of fast ripple detections were false positive. Inter-reader agreement for false positive fast ripple on spike classification was good (ICC = 0.713, 95% CI: 0.632-0.779). After removing false positive detections, the PPV of a single fast ripple on spike in an unresected electrode site for post-operative non-seizure free outcome was 85.7 [50-100%]. Including false positive detections reduced the PPV to 64.2 [57.8-69.83%].
Conclusions:
Applying automated HFO methods to intraoperative electrocorticography recordings results in false positive fast ripple detections. True fast ripples on spikes are rare, but predict non-seizure free post-operative outcome if found in an unresected site.
Significance:
Semi-automated HFO detection methods are required to accurately identify fast ripple events in intra-operative ECoG recordings.
More Related Videos
10:22Interictal High Frequency Oscillations Detected with Simultaneous Magnetoencephalography and Electroencephalography as Biomarker of Pediatric Epilepsy
Published on: December 6, 2016
05:42Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
Related Concept Videos
IR Frequency Region: Fingerprint Region
IR Frequency Region: X–H Stretching
IR Frequency Region: Alkyne and Nitrile Stretching
Comparing the stretching vibrational frequency of C≡C triple bonds with that of double and single bonds, it is evident that C≡C triple bonds exhibit a higher stretching frequency than C=C double and C–C single bonds. Similarly, the C≡N triple bond...
IR Frequency Region: Alkene and Carbonyl Stretching
Stretching frequencies are affected by several factors, such as resonance, inductive effects, ring strain, dipole moment, and hydrogen bonding. Consequently, the stretching frequency of the carbonyl double bond...
Automatic Processing and Automatic Social Behavior
Reliability and Validity