Related Experiment Video
Updated: Feb 7, 2026

Imaging Glioma Initiation In Vivo Through a Polished and Reinforced Thin-skull Cranial Window
Published on: November 20, 2012
[Effect of different parts of skull thickness on stereotactic electroencephalogram in children]
1Department of Functional Neurosurgery, National Center for Children's Health, Beijing Children's Hospital, Capital Medical University, Beijing 100045, China.
Insights
Children
Area of Science:
- Pediatric Neurosurgery
- Neurology
- Medical Imaging
Background:
- Stereotactic electroencephalogram (SEEG) is an invasive diagnostic procedure.
- Accurate electrode placement and fixation are crucial for SEEG efficacy.
- Understanding pediatric cranial bone thickness is vital for surgical planning.
Purpose of the Study:
- To measure cranial bone thickness in children during SEEG procedures.
- To assess the impact of bone thickness on electrode fixation.
- To evaluate the safety and reliability of robot-assisted SEEG in pediatric epilepsy.
Main Methods:
- Retrospective analysis of 13 children undergoing robot-assisted SEEG (ROSA).
- Measurement of skull thickness at electrode sites using post-operative CT scans.
- Recording of electrode screw loosening and adverse events.
Main Results:
- Significant variations in cranial bone thickness were observed across different skull regions (P<0.01).
- Temporal bone was the thinnest (3.5±1.3 mm), while occipital bone was the thickest (6.9±0.5 mm).
- Minor screw loosening occurred in 4 electrodes (3.5%), primarily in the temporal bone, without affecting SEEG recordings or causing adverse events.
Conclusions:
- Pediatric cranial bone is thinner than adult bone.
- Robot-assisted SEEG is a safe and reliable procedure for children with epilepsy.
- The observed screw loosening did not compromise SEEG data quality or patient safety.
Abstract:
Objective: To investigate the thickness of cranial bone in different parts of children skull during stereotactic electroencephalogram (SEEG) and its effect on electrode fixation. Methods: From October 2016 to March 2017, 13 children with SEEG by robot of surgery assistant (ROSA) were selected. The basic case information and electrode design scheme were collected. The skull thickness of each electrode channel was measured on post-operation CT, and the loosening of the fixed screws were recorded. The thickness of skull in frontal bone, temporal bone, parietal bone and occipital bone was statistically processed by SPSS statistical software. Results: There were total 113 electrodes in 13 children with epilepsy. There were 45 electrodes at frontal bone, of which the thickness was (5.7±2.8)mm. There were 34 electrodes at temporal bone, of which the thickness was (3.5±1.3)mm.There were 16 electrodes at parietal bone, of which the thickness was (6.0±2.5)mm.There were 18 electrodes at occipital bone, of which the thickness was (6.9±0.5)mm. Statistics showed that there was significant difference between differnt bone (F=15.340, P<0.01). There were 4 electrodes loosening, 1 at frontal bone and 3 at temporal bone, when the screws were removed. There was no adverse event related to the implantation of electrodes. Conclusions: The children's skull thickness is thinner than adults. The screw loosening is exist in some cases, but it has no effect on SEEG recording. No SEEG related adverse events are found in this group. Therefore, ROSA guided SEEG is safe and reliable in children with epilepsy.
Related Concept Videos
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Overview of the Skull
The cranial vault surrounds and protects the brain and houses the middle and inner ear structures. This cavity is bounded superiorly by the rounded top of the skull, which...
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...
Drug Dosing: Infants and Children
Pedigree Analysis
Nature and Nurture