Jeong Min Kwon1,2, Jae Ho Jung1,2
1Department of Ophthalmology, Pusan National University School of Medicine, Yangsan, Korea.
Background:
To evaluate binocular summation ratio using contrast sensitivity (CS) testing and correlation between binocular summation and stereoacuity, and control scale in intermittent exotropia (IXT).
Methods:
We conducted a prospective case-control study. Thirty-seven IXT and 41 controls were evaluated with both monocular and binocular CS testing. We compared the binocular summation ratio of IXT to that of controls. Near and distance stereoacuity was assessed and office-based control scale was evaluated. We investigated correlation between binocular CS summation ratio and stereoacuity, and control scale in IXT, respectively.
Results:
IXT had lower binocular CS summation ratio than controls at 1.5 and 3.0 cycles/degree (1.01 ± 1.02 vs. 1.62 ± 1.88 and 1.17 ± 0.96 vs. 1.86 ± 1.75, Both P < 0.05). We found significant correlation between binocular CS summation ratio at 3.0 cycles/degree and both near and distance stereoacuity (r = -0.411, P = 0.012 and r = -0.624, P = 0.005), and ratio at 1.5 cycles/degree also correlated significantly with distance stereoacuity (r = -0.397, P = 0.034) in the IXT. Binocular CS summation ratio was correlated to control scale at 1.5 and 3.0 cycles/degree (r = -0.327, P = 0.041 and r = -0.418, P = 0.028), and the ratio significantly differed in control scale groupings analysis at the same frequencies (Both P < 0.05).
Conclusion:
Our findings of subnormal binocular CS summation ratio in IXT had correlation with stereoacuity and control scale suggest that binocular CS testing may be a useful method in assessing binocular visual function in IXT.
Related Concept Videos
Summation Notation
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Patient-centered Care