Permanent pacemaker implantation after transcatheter aortic valve replacement in bicuspid aortic valve patients
Tian-Yuan Xiong1, Yan-Biao Liao1, Yi-Jian Li1
1Department of Cardiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
Background:
Studies of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) specifically for bicuspid aortic valve (BAV) patients are lacking. We aim to delineate possible aspects that might affect the incidence of PPI in a retrospective cohort of BAV patients treated with early-generation self-expanding devices.
Methods:
A total of 80 patients with bicuspid morphology who successfully underwent TAVR by self-expanding devices without prior PPI were included. Baseline clinical, echocardiographic, and angiographic characteristics, procedural and post-procedural details were collected.
Results:
The incidence of PPI after early-generation self-expanding valves in this BAV cohort was 26.3%. Baseline characteristics were comparable between patients requiring PPI post-TAVR or not. Perimeter oversizing greater than 20% significantly increased the risk of PPI compared with an oversizing of 10-20% (OR 5.08 [1.22, 21.07], P = 0.03). The proportion of patients with a depth of implantation greater than 6 mm was significantly higher in those who required PPI (82.4% vs 54.3%, P = 0.04). When testing the impact of depth of implantation >6 mm and oversizing in different morphologies, only in type 1 bicuspid patients and by oversizing>20% increased the risk of PPI (OR 12.00 [1.25, 115.36], P = 0.03) compared with an oversizing of 10-20%.
Conclusions:
Excessive perimeter oversizing in relation to aortic annulus and depth of implantation greater than 6 mm should be avoided to improve PPI post-TAVR for BAV patients receiving self-expanding devices, especially for type 1 BAV.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Aortic Regurgitation I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Aortic Regurgitation III: Medical Management