Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires
Published on: July 24, 2018
Flexural properties of rectangular nickel-titanium orthodontic wires when used as ribbon archwires
Objective:
To compare the flexural properties of rectangular nickel-titanium (Ni-Ti) orthodontic wires in occlusoapical and faciolingual orientations using a standardized test method.
Materials And Methods:
Twenty-two rectangular Ni-Ti wire groups were tested in occlusoapical (ribbon) orientation: eight conventional Ni-Ti products, five superelastic Ni-Ti products, and nine thermal Ni-Ti products (n = 10 per group). Six products of thermal Ni-Ti wire were tested in faciolingual (edgewise) orientation. A three-point bending test was performed to measure deactivation force at 3.0-, 2.0-, 1.0-, and 0.5-mm deflections of each rectangular wire at 37.0 ± 0.5°C. Analysis of variance and post hoc Student-Newman-Keuls tests were used to compare the mean values of the different groups (α = .05).
Results:
The ranges of deactivation forces varied greatly with different kinds, sizes, products, and deflections of Ni-Ti wires. One product of conventional and superelastic Ni-Ti wires had steeper force-deflection curves. Four products had similarly shaped flat force-deflection curves, whereas the sixth product had a moderately steep force-deflection curve. Thermal Ni-Ti wires had smaller deactivation forces ranging from 0.773 N (78.8 g) to 2.475 N (252.4 g) between deflections of 1.0 and 0.5 mm, whereas wider ranges of force from 3.371 N (343.7 g) to 9.343 N (952.7 g) were predominantly found among conventional Ni-Ti wires between deflections of 3.0 and 2.0 mm.
Conclusions:
Clinicians should critically select archwires for use in the occlusoapical orientation not only based on Ni-Ti wire type, size (0.022 × 0.016-in or 0.025 × 0.017-in), and product but also with deactivation deflections from 0.5 and 1.0 mm to obtain light forces in the occlusoapical orientation.
Related Concept Videos
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Curvilinear Motion: Rectangular Components
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the...
Rectangular and Triangular Pulse Function
For example, consider a rectangular pulse with a 5V amplitude, a 3-second duration, and centered at t=2 seconds. This pulse can be expressed using the rectangular function, written as,
Distribution of Stresses in a Narrow Rectangular Beam
Magnetic Field Due to Two Straight Wires