Related Experiment Video
Updated: Feb 7, 2026

Arterial Pouch Microsurgical Bifurcation Aneurysm Model in the Rabbit
Published on: May 14, 2020
Flow diverter for endovascular treatment of intracranial mirror segment internal carotid artery aneurysms
Anna Luisa Kühn1, Peter Kan2, Visish Srinivasan2
11 Department of Radiology and New England Center for Stroke Research, University of Massachusetts, Worcester, USA.
Background:
To evaluate the feasibility and efficacy of the pipeline embolization device in the treatment of unruptured intracranial mirror segment aneurysms.
Methods:
Out of a total of 338 subjects, 14 were identified harboring a total of 32 internal carotid artery mirror segment aneurysms that were treated with the pipeline embolization device and were consecutively enrolled into our study. We collected data on patient demographics, modified Rankin scale (mRS) at admission, aneurysm characteristics, clinical outcome at discharge, 3-9 and at 12-18 months as well as angiography results at follow-up.
Results:
Patients' mean age was 52.9 years; baseline mRS was 0 in all subjects. Pipeline embolization device placement was successful in all cases. Post-treatment mRS remained 0 in 13/14 patients. One patient experienced a small intraparenchymal hemorrhage and subarachnoid hemorrhage, associated with a frontoparietal infarction resulting in right upper extremity weakness and aphasia (post-treatment mRS 3). His mRS evaluation remained stable at the 3-9-month follow-up. Three to 9-month follow-up angiography (13/14 subjects) showed complete aneurysm occlusion in 24/30 aneurysms (80%), near complete and partial occlusion in three of 30 (10%) aneurysms each. At the 9-month follow-up, one patient experienced a complete occlusion of the anterior temporal artery branch but did not present with any clinical deficits. No mRS changes were encountered over a median 6-month follow-up period. Mid-term follow-up angiography (12-18 months) available in eight of 14 subjects showed complete aneurysm occlusion in all patients. Mild intimal hyperplasia was observed in one patient.
Conclusions:
Flow diversion technology can be used for the treatment of unruptured mirror segment aneurysms in selected patients.
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Phosphodiesterase Inhibitors
Among the PDE5 inhibitors, sildenafil (Revatio) stands out as a competitive and selective inhibitor. It operates by elevating cellular levels of cGMP and augmenting signaling through the cGMP-PKG pathway, promoting vasodilation. Upon oral...
Internal Energy
Internal Energy
Internal Receptors
Treatment for Pulmonary Arterial Hypertension: Endothelin Receptor Antagonists
ETs are synthesized through a complex sequence of enzymatic steps, primarily involving an enzyme referred to as endothelin-converting enzyme...
Treatment for Pulmonary Arterial Hypertension: Prostacyclin Receptor Agonists
These agonists bind to the IPR receptor situated on the plasma membrane of the pulmonary artery smooth muscle cells. This binding triggers a cascade of reactions known as the GS-AC-cAMP-PKA pathway. This pathway results in the relaxation of smooth muscle...

