Related Experiment Video
Updated: Feb 6, 2026

An Orthotopic Resectional Mouse Model of Pancreatic Cancer
Published on: September 24, 2020
Results of a randomized controlled trial comparing closed-suction drains versus passive gravity drains after
Filip Čečka1, Bohumil Jon1, Pavel Skalický2
1Department of Surgery, Medical Faculty and University Hospital Hradec Králové, Czech Republic.
Background:
This dual-center, randomized controlled trial aimed to compare 2 types of intra-abdominal drains after pancreatic resection and their effect on the development of pancreatic fistulae and postoperative complications.
Methods:
Patients undergoing pancreatic resection were randomized to receive either a closed-suction drain or a closed, passive gravity drain. The primary endpoint was the rate of postoperative pancreatic fistula. A secondary endpoint was postoperative morbidity during follow-up of 3 months. The planned sample size was 223 patients.
Results:
A total of 294 patients were assessed for eligibility, 223 of whom were randomly allocated. One patient was lost during follow-up, and 111 patients in each group were analyzed. The rate of postoperative pancreatic fistula (closed-suction 43.2%, passive 36.9%, P = .47) and overall morbidity (closed-suction 51.4%, passive 40.5%, P = .43) were not different between the groups. We did not find any differences between the groups in reoperation rate (P = .45), readmission rate (P = .27), hospital stay (P = .68), or postoperative hemorrhage (P = .11). We found a significantly lesser amount of drain fluid in the passive gravity drains between the second and fifth postoperative days and also on the day of drain removal compared with closed-suction drains.
Conclusion:
The type of drain (passive versus closed suction) had no influence on the rate of postoperative pancreatic fistulae. The closed-suction drains did not increase the rate of postoperative complications. We found that the passive gravity drains are more at risk for obstruction, whereas the closed-suction drains kept their patency for greater duration.
Related Concept Videos
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Responses to Gravity and Touch
Center of Gravity
Tracheostomy Suctioning II: Procedure
Work Done by Gravity
Like other forces, gravity does work on an object if it displaces it toward the Earth's center. In this case, the work done by gravity is said to be positive. If an external force acts on the object against the pull of gravity and manages to lift it away from the Earth's center, work is done against gravity. In this case, the net work done is said to be...
Suctioning the Nasopharyngeal Airway
Equipment Required