Massive transient pulmonary air embolism during permanent cardiac pacemaker implantation

Emre Ozdemir1, Fatma Kayaalti Esin1, Cem Nazli1

  • 1Katip Celebi University, Atatürk Training and Research Hospital, Cardiology Clinic, Izmir, Turkey.

Related Concept Videos

Pulmonary Embolism I: Introduction01:29

Pulmonary Embolism I: Introduction

Pulmonary embolism (PE) occurs when a thrombus, fat or air embolus, amniotic fluid, or tumor tissue blocks one or more pulmonary arteries. These blockages originate in the venous system or the right side of the heart.EtiologyPE primarily arises from deep vein thrombosis (DVT) and other hypercoagulable states, such as inherited thrombophilias. Additional etiological factors include venous stasis, commonly seen in obesity, and endothelial injury from surgery and trauma. Less common causes include...
735
Pulmonary Embolism III: Nursing Management01:27

Pulmonary Embolism III: Nursing Management

A pulmonary embolism occurs when a thrombus, amniotic fluid, tumor tissue, fat, or air embolus blocks one or more pulmonary arteries. Effective nursing management and patient education are crucial for improving outcomes and preventing recurrence.Nursing management starts with obtaining a comprehensive patient history, particularly noting any history of deep vein thrombosis (DVT). Assess for clinical manifestations, including dyspnea, chest pain, crackles, heart murmurs, and signs of right-sided...
448
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care01:29

Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care

Diagnosing Pulmonary EmbolismDiagnosing pulmonary embolism (PE) involves clinical assessment and advanced imaging tests. The preferred diagnostic tool is the spiral (helical) CT scan or CT angiography (CTA), which uses intravenous contrast media to visualize the pulmonary vasculature and identify emboli.A ventilation-perfusion (V/Q) scan is an alternative for patients unable to receive contrast media. This scan includes both perfusion and ventilation scanning. Perfusion scanning involves...
462
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
422
Air-entraining Agents01:27

Air-entraining Agents

Air-entraining agents improve the durability and workability of concrete in climates with frequent freezing and thawing. These agents prevent cracks by introducing small air bubbles into the mix, creating spaces accommodating water expansion when temperatures drop. The air-entraining agents lower the surface tension of water, forming stable, small air bubbles. This method is more effective than having accidental large voids, as the intentional, smaller, and evenly distributed air voids improve...
275
Transient and Steady-state Response01:24

Transient and Steady-state Response

In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...