Background And Objective:
Virtual bronchoscopic navigation (VBN) entails the provision of a virtual display of the bronchial routes that lead to small peripheral pulmonary lesions (PPL). It has been predicted that a combination of computed tomography (CT)-guided transbronchial biopsy (CT-TBB) with VBN might improve the diagnostic yield for small PPL. This study sought to investigate that prediction.
Methods:
A total of 100 patients with small PPL (<20 mm) were enrolled for CT-TBB and randomly allocated to either a VBN+ or VBN- group (50 subjects per group). Group results were then compared in terms of diagnostic yield, whole procedure time, times at which the first CT scan and biopsy were taken and the number of lung biopsy specimens retrieved.
Results:
The diagnostic yield for small PPL was significantly higher in the VBN+ group versus VBN- group (84% vs 58%, respectively (P = 0.013)), with no significant difference in (whole) examination time between groups (VBN+: 32:53 (32 min and 53 s) ± 12:01 vs VBN-: 33:06 ± 10:08 (P = NS)). However, the time periods between commencing the examination and either the first CT scan or first biopsy were significantly shorter for the VBN+ group, while the net biopsy time tended to be longer for this group with a significantly higher number of specimens collected (VBN+: 3.54 ± 1.07 specimens vs VBN-: 2.98 ± 1.06 specimens (P = 0.01)).
Conclusion:
Combining VBN with CT-TBB significantly improved the diagnostic yield for small PPL.
Related Concept Videos
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
ATP Yield
The ETC is embedded in the inner mitochondrial membrane and is comprised of four main protein complexes and an ATP synthase. NADH and FADH2 pass electrons to these complexes, which pump protons into the intermembrane space. This distribution of...
Reaction Yield
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...