Related Experiment Video
Updated: Feb 6, 2026

Biomass Conversion to Produce Hydrocarbon Liquid Fuel Via Hot-vapor Filtered Fast Pyrolysis and Catalytic Hydrotreating
Published on: December 25, 2016
[Coal Combustion Reactivity of Different Metamorphic Degree and Structure Changes of FTIR Analysis in Pyrolysis
Abstract:
The combustion reaction of raw coals in the air was analyzed withThermal Gravimetric Analyzer 6300 and FTIR (Fourier Transform infrared spectroscopy). The raw coals came from three different sources which were SL lignite, SH bitumite and TT anthracite. The chars were prepared by fixed bed pyrolysis equipment in different reaction temperature. The overlapping peaks were fitted into some sub-peaks by Gaussian function. The aromatic index (R), aromatic structure fused index (D) and organic maturity index (C) were calculated through sub-peaks areas. It showed that three kinds of ignition temperature of SL, SH and TT were 299.3, 408.2 and 441.0 ℃ respectively. The peak temperature of maximum weight loss rate were 348.6, 480.5 and 507.0 ℃ respectively. With the increase of coal rank, both ignition temperature and peak temperature of maximum weight loss rate increased in some degree. The result showed that coal structure was very complex. Vibration absorption peaks of hydroxyl (—OH), aliphatic hydrocarbons (—CH2,—CH3), aromatic (CC), oxygen-containing functional group(CO, C—O) and other major functional groups could be observed in the infrared spectral curves of all samples. With the increase of pyrolysis temperature, infrared vibration absorption peaks of aliphatic hydrocarbons (—CH2—, —CH3) were gradually decreased. the stretching vibration peak of CO which was at 1 700 cm-1 almost disappeared after coked at 550 ℃. SL samples’ absorption peak area infrared curve of oxygen functional groups at 1 000~1 800 cm-1 was more complex. With the increase of coking temperature they changed more significantly compared with others. While peak position and peak intensity for aromatic CC absorption peaks of SH and TT did not change apparently when temperature was changing. Variation trends of main functional groups among three ranks of coals were obviously different with changes of R, D and C values.
More Related Videos
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
07:58Improving the Combustion Performance of a Hybrid Rocket Engine using a Novel Fuel Grain with a Nested Helical Structure
Published on: January 18, 2021
Related Concept Videos
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily assigned.
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily...
Chromatin Structure Regulates pre-mRNA Processing
The chromatin structure, especially...
Degree of Unsaturation
The degree of unsaturation for hydrocarbons is U = (2C + 2 − H) / 2, where C is the number of carbon atoms and H is the number of hydrogen atoms.
Radian and Degree Measure