Using a Chemical Biopsy for Graft Quality Assessment
Published on: June 17, 2020
[The Quality Assessment and Selection of Dynamic Spectrum Signal]
Abstract:
Near infrared spectroscopy analysis, as a kind of nondestructive real-time continuous detection method, has provided ideas for the noninvasive measurement of blood components. In this article, in order to ensure the accuracy and reliability of the collected spectral data, the 405 acquired samples are evaluated by combining valid single edge counts of dynamic spectrum pulse wave in the time domain with the quality factor Q value of dynamic spectrum pulse wave in the frequency domain. As a result, the abnormal samples are removed and 218 cases of valid samples are selected. We use the dynamic spectrum data of the selected 218 samples as the experimental group and another 218 samples as a control group modeling analysis with the hemoglobin concentration of the corresponding samples. Each group select 200 cases of samples as a calibration set and 18 cases of sample as a prediction set. The prediction accuracy of the experimental group reach 93.8%. The prediction accuracy of the two control group respectively evaluated by the valid single edge counts or Q value are 65.6% and 67.7% and the three unfiltered control groups are 53.7%, 33.3%, 42.6% respectively. The prediction mean relative error (MSEP) of the experimental group is 0.067 5, the other two control groups are 0.072 3 and 0.072 2, and the other three control groups are 0.082.3, 0.078 9, 0.082 8. So compared with another control groups, the MSEP of the experimental group is the minimal. The results show that the filtering method of the spectral data samples through combining time domain with frequency domain is reliable and effective.this will provide a method to the precision research of dynamic spectrum noninvasive detection.
Related Concept Videos
The Electromagnetic Spectrum
The Electromagnetic Spectrum
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
Mass Spectrum
UV–Vis Spectrum
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...