Objectives:
The aim of this study was to test the hypothesis that magnetic resonance imaging (MRI) of the knee with 10-minute 3-dimensional (3D) controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) sampling perfection with application optimized contrast using different flip angle evolutions (SPACE) turbo spin echo (TSE) protocols can replace 20-minute 2-dimensional (2D) TSE standard-of-reference protocols for the diagnosis of internal derangement.
Materials And Methods:
After internal review board approval and prospective informed consent, 100 symptomatic subjects underwent MRI of the knee at 3 T and 50 symptomatic subjects at 1.5 T, consisting of 10-minute 3D CAIPIRINHA SPACE TSE and 20-minute standard-of-reference 2D TSE protocols. Two fellowship-trained musculoskeletal radiologists assessed the studies in an anonymized and randomized fashion for structural abnormalities. Descriptive statistics, interreader reliability, intermethod concordance, diagnostic definitiveness, and interchangeability tests were applied. P values equal to or smaller than 0.01 were considered significant.
Results:
The interchangeability analysis showed that the 3D MRI can replace the 2D MRI protocols, whereas a superiority of 3D MRI was suggested statistically for the detection of medial and lateral meniscal tears, cartilage defects, and bone marrow edema by significantly higher common pair exact match proportions of readers (P < 0.01, respectively).The overall interreader reliabilities were 89% of exact matches for 2D TSE (κ, 0.842) and 96% of exact matches for 3D TSE (κ, 0.941) (P < 0.01). There was good intermethod concordance (κ, 0.736; range, 0.579-1.000). The interreader reliability (2D TSE: κ, 0.748 [0.603-1.000]; 3D TSE: κ, 0.901 [0.797-1.000]) and diagnostic definitiveness were significantly higher for the 3D than 2D MRI (P < 0.01).
Conclusions:
10-minute 3D CAIPIRINHA SPACE TSE MRI protocols can replace 20-minute 2D TSE standard-of-reference MRI protocols for the evaluation of internal derangement of the knee by producing similar results in individual patient diagnoses, whereas interpretations of 3D CAIPIRINHA SPACE TSE MRI examinations resulted in an overall higher interreader reliability, intermethod concordance, and reader definitiveness.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Reliability and Validity
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete