Related Experiment Video
Updated: Feb 6, 2026

Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Optic disc microvasculature dropout in primary open-angle glaucoma measured with optical coherence tomography
Tadamichi Akagi1,2, Linda M Zangwill1, Takuhei Shoji1,3
1Hamilton Glaucoma Center, Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA, United States of America.
Purpose:
To evaluate microvasculature dropout in the optic disc (Mvd-D) using optical coherence tomography angiography (OCTA) and investigate factors associated with Mvd-D in primary open-angle glaucoma (POAG) eyes.
Methods:
One hundred twenty-three eyes of 123 POAG patients were included from the Diagnostic Innovations in Glaucoma Study. The 3.0×3.0-mm optic nerve head OCTA scans were acquired using a spectral-domain OCT instrument. Images with whole-signal-mode were evaluated. Eyes were classified into 3 categories (Mvd-D, pseudo-Mvd-D, and no Mvd-D). Mvd-D and pseudo-Mvd-D had complete loss of OCTA signals on the temporal side of the optic disc on the en face projection image. They were distinguished base on the visualization of the anterior lamina cribrosa in the horizontal B-scans of that area. No Mvd-D was defined when no complete signal loss of OCTA signals was observed. Covariates including focal lamina cribrosa defects assessed by swept-source OCT and microvasculature dropout in the parapapillary region (Mvd-P) were analyzed.
Results:
Forty-two, 37, and 44 eyes were identified as having Mvd-D, pseudo-Mvd-D, and no Mvd-D, respectively. The eyes with Mvd-D showed significantly lower intraocular pressure, worse visual field mean deviation, larger cup-to-disc ratio, thinner circumpapillary retinal nerve fiber layer (cpRNFL), and lower circumpapillary vessel density within the RNFL than the eyes with pseudo-Mvd-D or the eyes without Mvd-D. Multivariable logistic regression analysis showed significant associations of Mvd-D with larger cup-to-disc ratio (OR, 1.08; P = 0.001), worse visual field mean deviation (OR, 1.09; P = 0.048), higher prevalence of focal lamina cribrosa defect (OR, 9.05; P = 0.002), and higher prevalence of Mvd-P (OR, 10.33; P <0.001).
Conclusions:
OCTA-derived Mvd-D was strongly associated with the presences of Mvd-P and focal lamina cribrosa defects, and these 3 findings were topographically associated with each other.
More Related Videos
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
07:44In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Properties of Enantiomers and Optical Activity
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Glaucoma: Overview
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...