Published on: January 22, 2017
Determination of iodine in polyamide by inductively-coupled plasma/mass spectrometry
Christine Devouge-Boyer1, Sarah Mouda1, Olivier Gueguen2
1Normandie Univ, INSA de Rouen, Université de Rouen, CNRS, COBRA (UMR 6014) Avenue de l'Université, 76800 Saint-Etienne-du-Rouvray, France.
Abstract:
A method was developed for the determination of iodine in polyamide (PA). This method is needed as PA containing iodine (such as CuI/KX (X = I or Br) heat stabilizing agent), may represent a risk of corrosion for electronic parts in the automotive industry. The method involved a microwave assisted digestion method using nitric acid followed by inductively coupled plasma mass spectrometry (ICP-MS) analysis. A dilution in 0.5% NH3 was needed prior to ICP-MS analysis to suppress memory effect. The limit of quantification was estimated to be 0.9 mg kg-1 which allows the control of very low iodine content PA used for applications in sensitive electronic parts. Spiking with iodide at 50 mg kg-1 gave recovery factors of 100 ± 0.8%. The acid digestion method was compared with microwave assisted extraction of PA with 5% NH3 solution. Alkaline extraction gave slightly lower results (10% below). Finally, the acid digestion method was applied to the analysis of raw materials PA pellets and molded parts (used or not). Obtained iodine contents were ranged from < 0.9-1000 mg kg-1 with relative standard deviation (RSD) on samples in the range 2.2-4.5%.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Mass Spectrometry: Overview
Tandem Mass Spectrometry