Related Experiment Video
Updated: Feb 6, 2026

Bedside Ultrasound for Guiding Fluid Removal in Patients with Pulmonary Edema: The Reverse-FALLS Protocol
Published on: July 28, 2018
Using Objective Fluid Balance Data to Identify Pulmonary Edema in Subjects With Ventilator-Associated Events
Wen-Cheng Chao1,2, Wei-Lun Chang3,4, Chieh-Liang Wu1,5
1Division of Chest Medicine, Department of Internal Medicine, Taichung Veterans General Hospital, Taichung, Taiwan.
Background:
A ventilator-associated events (VAEs) algorithm was developed to detect events in mechanically ventilated subjects using objective parameters, and we aimed to use objective data of fluid balance to identify pulmonary edema-associated VAEs.
Methods:
This single-center retrospective cohort study was conducted in a medical ICU and enrolled all mechanically ventilated patients between July 2016 and June 2017. Electronic medical records were reviewed to obtain data regarding ventilator-associated conditions (VACs), infection-related ventilator-associated complications (IVACs), possible ventilator-associated pneumonia (VAP), and traditionally defined VAP.
Results:
Of the 1,158 mechanically ventilated subjects, 85 (7.3%) subjects developed VAEs with a corresponding incidence rate of 7.7 events per 1,000 ventilator days. Among the 85 subjects with VAEs, 52 (61.2%) were classified as IVACs, while 23 (27.1%) had possible VAP. Notably, pulmonary edema was the main etiology (29.0%) for VAEs in the 62 subjects with non-possible VAP VAEs. Compared with those without pulmonary edema, subjects with pulmonary edema had a higher positive fluid balance 2 d before (+1,228 vs +173.5 mL, P = .005) and 1 d before (+1,622 vs +313 mL, P = .002) the diagnosis of VAE. In the multivariate logistic regression analysis (adjusted odds ratio [OR]) adjusted for potential confounders, an older age (adjusted OR 1.072, 95% CI 1.001-1.147), receiving renal replacement therapy (adjusted OR 8.906, 95% CI 1.454-54.558), and a positive cumulative difference between fluid balance 2 d and 1 d before VAE indexing (adjusted OR 1.527 per L positive, 95% CI 1.153-2.023) were independently associated with pulmonary edema in subjects with VAEs.
Conclusion:
These findings provide epidemiological evidence of VAEs in a medical ICU and showed that fluid balance may be used to identify pulmonary edema-associated VAEs. Further studies are warranted to validate and translate these findings into an automated surveillance system for VAEs.
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Assessment of the Gastrointestinal System I: Subjective Data
Health History
The initial step in assessing the GI system is obtaining a comprehensive health history. This includes inquiring about the patient's history or presence of problems...
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Balancing Redox Equations

