Phase-shifting differential interference contrast microscope with Savart shear prism and rotatable analyser

S-T Lin1, H-X Trịnh1, Z-W Chen1

  • 1Department of Electro-optical Engineering, National Taipei University of Technology, Taipei, Taiwan.

Journal of Microscopy
|August 9, 2018
PubMed
Summary

A new differential interference contrast microscope (DICM) enhances image contrast using shearing interferometry. This novel configuration, utilizing a Savart shear prism, demonstrates its validity and capability in experimental results.

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
13.7K
Interference and Diffraction02:18

Interference and Diffraction

Interference is a characteristic phenomenon exhibited by waves. When two electromagnetic waves interact with their peaks and troughs coinciding, a resulting wave with enhanced amplitude is produced. This is known as constructive interference. In this case, the two waves interacting are in phase with each other.
52.5K
Biot-Savart Law01:19

Biot-Savart Law

The Biot-Savart law gives the magnitude and direction of the magnetic field produced by a current. This empirical law was named in honor of two scientists, Jean-Baptiste Biot and Félix Savart, who investigated the interaction between a straight, current-carrying wire and a permanent magnet.
A current-carrying wire creates a magnetic field in its vicinity. Consider an infinitesimal current element dl in a wire. The direction of vector dl is along the direction of the current. The total magnetic...
9.0K
Biot-Savart Law: Problem-Solving00:59

Biot-Savart Law: Problem-Solving

The magnitude and direction of a magnetic field created by a steady current can be calculated using the Biot-Savart law.
Consider a mobile phone battery bank as a source of steady current, which flows through the wire connected between the two. What is the magnitude of the magnetic field created by this current at a field point P?
To estimate the magnitude of the total magnetic field, we first consider a small current element of length dl, at a distance r from the field point. Now the following...
3.9K
RNA Interference01:23

RNA Interference

RNA interference (RNAi) is a process in which a small non-coding RNA molecule blocks the post-transcriptional expression of a gene by binding to its messenger RNA (mRNA) and preventing the protein from being translated.
This process occurs naturally in cells, often through the activity of genomically-encoded microRNAs. Researchers can take advantage of this mechanism by introducing synthetic RNAs to deactivate specific genes for research or therapeutic purposes. For example, RNAi could be used...
28.1K
Shear Diagram01:27

Shear Diagram

In the study of beam mechanics, shear diagrams play a crucial role in understanding the distribution of shear forces along the length of a beam. Consider a beam AB that is supported at both ends and subjected to perpendicular loads.
First, a free-body diagram of the beam is drawn, representing all the external forces and internal reactions acting on the beam. One can calculate the reaction forces at each support by employing the equilibrium equations of force and moment. The vertical component...
1.7K