Characterization and adsorption capacity of potassium permanganate used to modify activated carbon filter media for

Shih-Cheng Hu1, Ying-Chen Chen2, Xin-Zhi Lin3

  • 1Department of Energy and Refrigerating Air-Conditioning Engineering, National Taipei University of Technology, No. 1, Sec. 3, Chung Hsiao E Road, Taipei, 10608, Taiwan, Republic of China.

Related Concept Videos

Oxidation of Alkenes: Syn Dihydroxylation with Potassium Permanganate02:21

Oxidation of Alkenes: Syn Dihydroxylation with Potassium Permanganate

Alkenes can be dihydroxylated using potassium permanganate.  The method encompasses the reaction of an alkene with a cold, dilute solution of potassium permanganate under basic conditions to form a cis-diol along with a brown precipitate of manganese dioxide.
16.8K
Active Filters01:25

Active Filters

Active filters are electronic circuits that use operational amplifiers (op-amps), resistors, and capacitors to filter out unwanted frequency components from a signal. A first-order low-pass active filter is designed to pass signals with a frequency lower than a certain cutoff frequency and attenuate frequencies higher than that cutoff frequency. The transfer function for a first-order low-pass active filter is:
1.3K
Antiepileptic Drugs: Potassium Channel Activators01:20

Antiepileptic Drugs: Potassium Channel Activators

Ezocgabine or retigabine, an antiepileptic drug of remarkable efficacy, has revolutionized the management of seizures. It is a potassium channel activator, explicitly targeting the family of Q subtype potassium channels. It enhances the transmembrane potassium currents, regulating neuronal excitability. This action stabilizes the resting membrane potential, a pivotal factor in mitigating the hyperexcitability that characterizes epilepsy.
Ezogabine has gained approval as an adjunctive treatment...
700
Lung Capacity01:47

Lung Capacity

The air in the lungs is measured in volumes and capacities. Lung volume measures reflect the amount of air taken in, released, or left over after a lung function, like a single inhalation. Lung capacity measures are sums of two or more lung volume measures.
56.4K
Passive Filters01:27

Passive Filters

Passive filters are utilized to shape the frequency spectrum of signals across a diverse array of applications. These filters, using only passive elements like resistors (R), inductors (L), and capacitors (C), are capable of selectively allowing or blocking certain frequency ranges without the need for external power sources.
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
1.0K
Analyte Adsorption and Distribution01:09

Analyte Adsorption and Distribution

In certain chromatographic separations, solutes transfer between the mobile phase and the stationary phase via sorption, which typically refers to the process of adsorption. For many chromatographic systems, the sorption process often depends on the polarity of the compounds—an expression of the overall dipole moment within the molecule. During the separation process, there is competition between the solute and solvent for adsorption to the stationary phase. Highly polar compounds and...
2.8K