Non-Invasive Pressure Reactivity Index Using Doppler Systolic Flow Parameters: A Pilot Analysis
Related Experiment Video
Updated: Feb 6, 2026

Blood Flow Imaging with Ultrafast Doppler
Published on: October 14, 2020
Frederick A Zeiler1,2,3, Peter Smielewski4, Andrew Stevens1
11 Divisions of Anaesthesia, Addenbrooke's Hospital, University of Cambridge , Cambridge, United Kingdom .
Abstract:
The goal was to predict pressure reactivity index (PRx) using non-invasive transcranial Doppler (TCD) based indices of cerebrovascular reactivity, systolic flow index (Sx_a), and mean flow index (Mx_a). Continuous extended duration time series recordings of middle cerebral artery cerebral blood flow velocity (CBFV) were obtained using robotic TCD in parallel with direct intracranial pressure (ICP). PRx, Sx_a, and Mx_a were derived from high frequency archived signals. Using time-series techniques, autoregressive integrative moving average (ARIMA) structure of PRx was determined and embedded in the following linear mixed effects (LME) models of PRx: PRx ∼ Sx_a and PRx ∼ Sx_a + Mx_a. Using 80% of the recorded patient data, the LME models were created and trained. Model superiority was assessed via Akaike information criterion (AIC), Bayesian information criterion (BIC), and log-likelihood (LL). The superior two models were then used to predict PRx using the remaining 20% of the signal data. Predicted and observed PRx were compared via Pearson correlation, linear models, and Bland-Altman (BA) analysis. Ten patients had 3-4 h of continuous uninterrupted ICP and TCD data and were used for this pilot analysis. Optimal ARIMA structure for PRx was determined to be (2,0,2), and this was embedded in all LME models. The top two LME models of PRx were determined to be: PRx ∼ Sx_a and PRx ∼ Sx_a + Mx_a. Estimated and observed PRx values from both models were strongly correlated (r > 0.9; p < 0.0001 for both), with acceptable agreement on BA analysis. Predicted PRx using these two models was also moderately correlated with observed PRx, with acceptable agreement (r = 0.797, p = 0.006; r = 0.763, p = 0.011; respectively). With application of ARIMA and LME modeling, it is possible to predict PRx using non-invasive TCD measures. These are the first and as well as being preliminary attempts at doing so. Much further work is required.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's...
Doppler Effect - I
Doppler Effect - II
Pilot and Numeric Relaying
Wave Parameters

