Effect of compression waveform and resuscitation duration on blood flow and pressure in swine: One waveform does not
Joshua W Lampe1, Tai Yin2, George Bratinov3
1The Feinstein Institute for Medical Research, Department of Emergency Medicine, Northwell Health, Manhasset, NY, United States; ZOLL Medical Corporation, Chelmsford, MA, United States.
Background:
Chest compression (CC) research primarily focuses on finding the 'optimum' compression waveform using a variety of compression efficacy metrics. Blood flow is rarely measured systematically with high fidelity. Using a programmable mechanical chest compression device, we studied the effect of inter-compression pauses in a swine model of cardiac arrest, testing the hypothesis that a single 'optimal' CC waveform exists based on measurements of resulting blood flow.
Methods:
Hemodynamics were studied in 9 domestic swine (∼30 kg) using multiple flow probes and standard physiological monitoring. After 10 min of ventricular fibrillation, five mechanical chest compression waveforms (5.1 cm, varying inter-compression pauses) were delivered for 2 min each in a semi-random pattern, totaling 50 compression minutes. Linear Mixed Models were used to estimate the effect of compression waveform on hemodynamics.
Results:
Blood flow and pressure decayed significantly with time in both arteries and veins. No waveform maximized blood flow in all vessels simultaneously and the waveform generating maximal blood flow in a specific vessel changed over time in all vessels. A flow mismatch between paired arteries and veins, e.g. abdominal aorta and inferior vena cava, also developed over time. The waveform with the slowest rate and shortest duty cycle had the smallest mismatch between flows after about 30 min of CPR.
Conclusions:
This data challenges the concept of a single optimal CC waveform. Time dependent physiological response to compressions and no single compression waveform optimizing flow in all vessels indicate that current descriptions of CPR don't reflect patient physiology.
More Related Videos
06:01Semi-Automated Analysis of Peak Amplitude and Latency for Auditory Brainstem Response Waveforms Using R
Published on: December 9, 2022
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
Related Concept Videos
Effective Value of a Periodic Waveform
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Self-Serving Bias
Blood Flow
Measurement of Blood Pressure