Related Experiment Video
Updated: Feb 6, 2026

High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Acute Left Ventricular Unloading Reduces Atrial Stretch and Inhibits Atrial Arrhythmias
Kiyotake Ishikawa1, Shin Watanabe1, Philyoung Lee1
1Cardiovascular Research Center, Icahn School of Medicine at Mount Sinai, New York, New York.
Background:
Left atrium (LA) physiology is influenced by changes in left ventricular (LV) performance and load.
Objectives:
The purpose of this study was to define the effect of acute changes in LV loading conditions on LA physiology in subacute myocardial infarction (MI).
Methods:
MI was percutaneously induced in 19 Yorkshire pigs. One to 2 weeks after MI, 14 pigs underwent acute LV unloading using a percutaneous LV assist device, Impella. The remaining 5 pigs underwent acute LV loading by percutaneous induction of aortic regurgitation. A pressure-volume catheter was inserted into the LA using a percutaneous transseptal approach, and LA pressure-volume loops were continuously monitored. Atrial arrhythmia inducibility was examined by burst-pacing of the right atrium. Nicotinamide adenine dinucleotide phosphate oxidase (NOX) levels and ryanodine receptor phosphorylation were examined in LA tissues to study the potential effect of stretch-dependent oxidative stress.
Results:
MI resulted in reduced LV ejection fraction and increased LV end-diastolic pressure with concomitant increase in LA pressure and volumes. Acute LV unloading resulted in a reduction of LV end-diastolic pressure, which led to proportional decreases in mean LA pressure and maximum LA volume. LA pressure-volume loops exhibited a pump flow-dependent, left-downward shift. This was associated with reduced LA passive stiffness, suggesting the alleviation of the LA stretch that was present after MI. Prior to acute unloading of the LV, 71% of the pigs were arrhythmia-inducible; LV unloading reduced this to 29% (p = 0.02). Time to spontaneous termination of atrial arrhythmias was decreased from median 55 s (range 5 to 300 s) to 3 s (range 0 to 59 s). In contrast, acute LV loading with aortic regurgitation increased LA pressure without a significant effect on arrhythmogenicity. Molecular analysis of LA tissue revealed that NOX2 expression was increased after MI, whereas acute LV unloading reduced NOX2 levels and diminished ryanodine receptor phosphorylation.
Conclusions:
Acute LV unloading relieves LA stretch and reduces atrial arrhythmogenicity in subacute MI.
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...
Feedback Inhibition
Mechanism of Cardiac Arrhythmias
IR Frequency Region: X–H Stretching
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...