Related Experiment Video
Updated: Feb 6, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Immediate Post-Procedural 12-Lead Electrocardiography as Predictor of Late Conduction Defects After Transcatheter
Troels H Jørgensen1, Ole De Backer1, Thomas A Gerds2
1Department of Cardiology, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.
Objectives:
The aim of this study was to use a 12-lead electrocardiogram obtained immediately post-transcatheter aortic valve replacement (TAVR) to identify predictors of late high-degree conduction defect (HD-CD) within 30 days after TAVR.
Background:
There are limited data on risk factors for the development of late HD-CD and the need to retain the temporary pacemaker after TAVR.
Methods:
A single-center study was conducted including 467 consecutive patients, without pre-procedural pacemakers, undergoing TAVR.
Results:
Self-expandable, mechanical, or balloon-expandable heart valves were implanted in 328 (70%), 61 (13%), and 78 (17%) patients, respectively. For patients in sinus rhythm without right bundle branch block, late HD-CD developed in 0 of 70 patients (0%; 95% confidence interval [CI]: 0% to 5.1%) with PR interval <200 ms and QRS interval <120 ms and in 5 of 109 patients (4.6%; 95% CI: 1.5% to 10.4%; all with sufficient escape rhythm) with PR interval <240 ms and QRS interval <150 ms. Late HD-CD developed in 14 of 101 patients (13.9%; 95% CI: 7.8% to 22.2%; 6 with insufficient escape rhythm [5.9%; 95% CI: 2.2% to 12.5%]) with PR interval ≥240 ms or QRS interval ≥150 ms. Furthermore, late HD-CD developed in 3 of 49 patients (6.1%; 95% CI: 1.3% to 16.9%; all with sufficient escape rhythm) and in 3 of 30 patients (10.0%; 95% CI: 2.1% to 26.5%; 2 with insufficient escape rhythm [6.7%; 95% CI: 0.8% to 22.1%]) with atrial fibrillation and no right bundle branch block with QRS interval <140 and ≥140 ms, respectively.
Conclusions:
On the basis of immediate post-TAVR 12-lead electrocardiography, removing the temporary pacemaker immediately following TAVR is potentially safe in patients without right bundle branch block who are: 1) in sinus rhythm with PR interval <240 ms and QRS interval <150 ms; or 2) in atrial fibrillation with a QRS interval <140 ms.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Handwashing III: During the Procedure and Post-Procedure Steps
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Conduct Disorder