Predictors of Advanced Conduction Disturbances Requiring a Late (≥48 H) Permanent Pacemaker Following Transcatheter
Antonio Mangieri1, Giuseppe Lanzillo1, Letizia Bertoldi1
1IRCCS San Raffaele Scientific Institute, Milan, Italy.
Objectives:
This study sought to determine predictors of advanced conduction disturbances requiring late (≥48 h) permanent pacemaker replacement (PPM) after transcatheter aortic valve replacement (TAVR).
Methods:
Data of consecutive patients were identified by retrospective review of a TAVR database of a single center in Milan, Italy, between October 2007 and July 2015. We defined delta PR (ΔPR) and delta QRS (ΔQRS) interval as the difference between the last PR and QRS length available 48 h after TAVR and the baseline PR and QRS length.
Results:
Overall population included 740 patients. We excluded 78 patients who already had a PPM and 51 patients who received a PPM <48 h after TAVR. The final analysis included 611 patients. Fifty-four patients (8.8%) developed an advanced conduction disturbance requiring PPM ≥48 h following TAVR. Patients who required a late PPM implant had a wider QRS width (113 ± 25 ms vs. 105 ± 23 ms; p = 0.009) and a higher prevalence of baseline right bundle branch block (12.9% vs. 5.3%; p = 0.026) and were more likely to have a self-expandable valve implanted (51.8% vs. 31.9%; p = 0.003). The ΔPR was 40 ± 51 ms (p = 0.0001) and the ΔQRS was 22 ± 61 ms (p = 0.001). Multivariable analysis revealed that baseline right bundle branch block (odds ratio: 3.56; 95% confidence interval: 1.07 to 11.77; p = 0.037) and ΔPR (odds ratio for each 10-ms increase: 1.31; 95% confidence interval: 1.18 to 1.45; p = 0.0001) are independent predictors of delayed advanced conduction disturbances.
Conclusions:
This analysis showed that baseline right bundle branch block and the amount of increase of PR length after TAVR are independent predictors of late (≥48 h) advanced conduction disturbances requiring PPM replacement after TAVR in this cohort. A simple ECG analysis could help in detecting potentially lethal advanced conduction disturbances that could occur more than 48 h after TAVR.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Ecological Disturbance
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Requirements for Human Life
Oxygen
Atmospheric air is only about 20 percent oxygen, but that oxygen is a key component of the chemical reactions that keep the body alive, including the reactions that produce ATP. Brain cells are susceptible to a lack of oxygen because they require a...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduct Disorder