3-D Neural denoising for low-dose Coronary CT Angiography (CCTA)
Michael Green1, Edith M Marom2, Eli Konen2
1School of Electrical Engineering, Tel-Aviv University, Ramat-Aviv, Israel.
Abstract:
CCTA has become an important tool for coronary arteries assessment in low and medium risk patients. However, it exposes the patient to significant radiation doses, resulting from high image quality requirements and acquisitions at multiple cardiac phases. For widespread use of CCTA for coronary assessment, significant reduction of radiation exposure with minimal image quality loss is still needed. A neural denoising scheme, relying on a fully convolutional neural network (FCNN) architecture, is developed and applied to noisy CCTA. In contrast to previously published methods, the proposed FCNN is trained directly on 3-D CT data patches (blocks), implementing 3-D convolutions. Considering that anatomy is inherently tridimensional, the proposed 3-D approach may better capture and enforce inter-slice continuity of tiny structures. While training is performed on individual blocks, whole input scans can be fed and denoised in one piece, thus leveraging the fully convolutional architecture to maximize processing speed. The proposed method is compared to state-of-the-art denoising algorithms on a dataset of 45 CCTA scans. Low-dose scans are simulated by synthetic Poisson noise applied to the sinogram corresponding to a 90% reduction in radiation dose. The average feature similarity score (0.864) and the peak signal-to-noise ratio (41.47) obtained for the proposed algorithm outperformed the compared methods while requiring significantly shorter processing time. A set of 2-D FCNNs, structurally similar to the proposed 3-D network, are also implemented to demonstrate contribution of the additional dimension to the improved denoising. For further validation of the method coronary reconstruction using the Intellispace cardiac tool (Philips, Holland) is performed both on a real noisy CCTA scan and on the denoised scan using the proposed method. It is shown that the cardiac tool succeeds in reconstructing more coronaries using the scan denoised by the proposed method. The obtained results suggest the proposed method provides an efficient and powerful approach to low-dose CCTA denoising.
More Related Videos
Related Concept Videos
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Neural Regulation
Radiological Investigation I: X-ray and CT