Objective:
The purpose of this study was to evaluate the use of a noncontrast MRI protocol that includes a cisternographic sequence (CISS/FIESTA/3D DRIVE) compared to a protocol that includes a gadolinium-enhanced sequence in order to determine whether a noncontrast approach could be utilized to follow vestibular schwannomas.
Methods:
A total of 251 patients with vestibular schwannomas who underwent MRI of the temporal bones that included both cisternographic sequence and postcontrast T1 imaging between January 2000 and January 2016 for surveillance were included in this retrospective study. The size of the vestibular schwannomas was independently assessed on a noncontrast MR cisternographic sequence and compared to size measurements on a postcontrast sequence. The evaluation of intralesional cystic components (identified as T2 signal hyperintensity) and hemorrhagic components (identified with intrinsic T1 hyperintensity) on noncontrast MR sequences was compared to evaluation on postcontrast MR sequences to determine whether additional information could be derived from the postcontrast sequences. Additionally, any potentially clinically significant, incidentally detected findings on the postcontrast T1 sequences were documented and compared with the detection of these findings on the precontrast images.
Results:
No significant difference in vestibular schwannoma size was found when comparing measurements made on the images obtained with the MR cisternographic sequence and those made on images obtained with the postcontrast sequence (p = 0.99). Noncontrast MR images were better (detection rate of 87%) than postcontrast images for detection of cystic components. Noncontrast MR images were also better for identifying hemorrhagic components. No additional clinically relevant information regarding the tumors was identified on the postcontrast sequences.
Conclusions:
Based on the results of this study, a noncontrast MR protocol that includes a cisternographic sequence would be sufficient for the accurate characterization of size and signal characteristics of vestibular schwannomas, obviating the need for gadolinium contrast administration for the routine surveillance of these lesions.
Related Concept Videos
The Vestibular System
Principles of Disease Surveillance
Imaging Studies VII: Vascular Imaging
Immune Surveillance by NK Cells and Phagocytes
Natural Killer Cells: The Fast Responders
NK cells are large granular lymphocytes found in the blood and lymphatic system. These...
X-ray Imaging
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...