Related Experiment Video
Updated: Feb 6, 2026

Arthroscopic Management of Massive Irreparable Rotator Cuff Tears: Whole Rotator Cable Reconstruction Using Proximal Biceps Tendon Autograft
Published on: June 6, 2025
The absorbable subacromial spacer for irreparable posterosuperior cuff tears has inconsistent results
Miguel Angel Ruiz Ibán1, Rafael Lorente Moreno2, Raquel Ruiz Díaz3
1Hospital Universitario Ramón y Cajal, Cta Colmenar km 9.100, Madrid, Spain. drmri@hotmail.com.
Purpose:
To evaluate the 2-year results of an absorbable subacromial spacer in patients with irreparable posterosuperior rotator cuff tears.
Methods:
Prospective longitudinal study of a consecutive case series of 16 subjects with irreparable tears of the posterosuperior rotator cuff in which the InSpace® subacromial spacer was arthroscopically implanted. A full clinical evaluation that included the Constant test, Simple Shoulder Test (SST) and the QuickDash questionnaire was performed preoperatively and at 12 and 24 months follow-up. The primary outcome for assessing the success of the procedure was a variable composed of a clinically relevant variation of the Constant (established in an improvement greater than 10 points) and the absence of surgical reintervention.
Results:
Fifteen subjects (11 women/4 men, median age = 69.4 years [interquartile range 7.50], range 60-80 years) completed the 2-year of follow-up. According to the main evaluation criteria, only 6 patients (40%) had a successful outcome. Five subjects required reconversion to a reverse shoulder arthroplasty (at a median of 9.8 months postoperatively) due to absence of clinical improvement or worsening of symptoms. Of the ten remaining subjects, only 6 had improvements greater than 10 points in the Constant score. Despite of this, these 10 subjects had, on average, some improvement in the Constant test (preoperative Constant: median 35.0 [27.0-52.5] vs Constant at 24 months: 53.5 [55.0-84.0], significant differences p = 0.02), in the SST (3.0 [2.0-4.0] vs 6.0 [3.25-7.75], p = 0.039) and in the QuickDASH test (37.0 [33.25-40.0] vs 27.5 [20.5-32.75], p = 0.012).
Conclusions:
The outcomes of the implantation of the subacromial biodegradable spacer at 2-year follow-up are not satisfactory. In this small case series only 40% of patients seem to clearly benefit from surgery. One in three required revision to a reverse shoulder arthroplasty. The described technique does not seem a reasonable alternative for the management of the majority of patients with irreparable ruptures of the rotator cuff. The indications of this device should be more clearly defined.
Level Of Evidence:
IV.
More Related Videos
Related Concept Videos
CRISPR and crRNAs
The CRISPR-Cas system stores a copy of foreign DNA in the host genome and uses it to identify the foreign DNA upon reinfection. CRISPR-Cas has three different...
Uncertainty in Measurement: Accuracy and Precision
Schemas
Cognitive Dissonance
Self-Evaluation: Self-Enhancement and Self-Verification
Ribosomal RNA Synthesis
Ribosome biogenesis begins with the synthesis of 5S and 45S pre-rRNAs by distinct RNA polymerases. The primary transcripts are extensively processed and modified before they are bound and folded by ribosomal proteins and assembly factors,...

