Related Experiment Video
Updated: Feb 6, 2026

In vivo Measurement of Knee Extensor Muscle Function in Mice
Published on: March 4, 2021
Differences in elbow extensor muscle characteristics between resistance-trained men and women
Justin J Merrigan1, Jason B White1,2, Y Eliot Hu2
1Division of Health and Human Performance, George Mason University, 10900 University Blvd, MS 4E5, Manassas, VA, 20110-2203, USA.
Purpose:
Muscular strength is suggested to be dependent upon muscle characteristics. Yet, sex-specific relationships of muscle characteristics to strength in the resistance-trained require investigation. Therefore, the purpose was to evaluate sex differences in muscle characteristics and isometric strength in the elbow extensors, as well as their respective associations.
Methods:
Resistance-trained men (n = 15, mean ± SD 22 ± 4 years, 87.5 ± 12.8 kg, 16.9 ± 2.9% body fat) and women (n = 15, mean ± SD 25 ± 5 years, 59.3 ± 7.3 kg, 22.4 ± 4.2% body fat) were tested. B-mode ultrasound images assessed muscle thickness, pennation angle, and echo intensity. Muscle volume and fascicle length were estimated from previously validated equations. Maximal voluntary isometric contraction measured elbow extensors isometric strength. Independent samples t-tests and Fisher's r-to-z test examined differences between sexes.
Results:
Sex differences existed in all muscle characteristics (p < 0.05). Men's absolute strength (27.86 ± 3.55 kg) was significantly greater than women (16.15 ± 3.15 kg), but no differences were noted when controlling for muscle volume (men 0.069 ± 0.017, women 0.077 ± 0.022 kg/cm3). Sex differences did not exist in the relationships of muscle characteristics to strength with muscle size having the largest correlations. However, the relationship between echo intensity and body fat was different in men (r = - 0.311) and women (r = 0.541, p = 0.0143).
Conclusions:
Sex differences in isometric elbow extensor strength are eliminated when expressed relative to muscle volume. Relationships of echo intensity and body fat were different between men and women and may be indicative of greater adipose infiltration in women.
Related Concept Videos
Specialized Characteristics of Cardiac Muscles
Cardiac muscle cells are smaller than skeletal muscles, averaging 10–20 mm in diameter and 50–100 mm in length. However, they have large energy demands for continuous contraction and relaxation. This energy is almost exclusively derived from aerobic metabolism of energy...
Characteristics of Life
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Identifying Statistically Significant Differences: The F-Test
Sum and Difference OpAmps
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...