A patient-specific haptic drilling simulator based on virtual reality for dental implant surgery
Xiaojun Chen1, Pengjie Sun2, Denghong Liao2
1School of Mechanical Engineering, Shanghai Jiao Tong University, Dongchuan Road 800, Minhang District, Room 805, Shanghai, 200240, China. xiaojunchen@sjtu.edu.cn.
Purpose:
In the dental implant surgery, there are inevitable risks due to the anatomically complex operation in the cranio-maxillofacial region. Therefore, there is a trend to use computer-aided technology to simulate the process of the implant surgery. In this study, we present a haptic simulator for trainees to study and rehearse the drilling performance of dental implant surgery.
Materials And Methods:
The dental implant surgery simulator (DISS) is developed based on the haptic force-feedback device Omega.6, and some free open-source software libraries such as Computer Haptics and Active Interface (CHAI3D), Qt and Visualization Toolkit. To achieve the desired effects of drilling, the meshes are subdivided with a recursive algorithm which breaks down a triangular patch into 4 sub-triangles. The drilling operation can be implemented at any specified location of the model. Once the drilling direction is determined, the position and rotation of the haptic device tool are constrained to the orientation through a dimension reduction algorithm. The driller diameter and drill speed are tunable to implement stepwise drilling for the patient-specific models.
Results:
A patient-specific drilling simulator based on virtual reality for dental implant surgery is presented. The simulation of stepwise drilling was conducted, and three patient-specific models reconstructed by Computed Tomography data were employed to help the novices to find the suitable drilling parameter.
Conclusion:
The obtained results showed that the haptic-based DISS could simulate various dental implant surgeries with different driller diameter and drill speed which takes patient-specific models as input. The evaluation of the DISS proves its good performance and it could provide an effective method to improve the skills and experiences of trainees.
Related Concept Videos
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
Principle of Virtual Work: Problem Solving
To apply the principle of virtual work,...
Virtual Work for a System of Connected Rigid Bodies
Next,...
Specific Heat
For example, increasing the temperature of one gram of water by 1°C requires one calorie of heat energy and can be written as 1 cal/g-°C, or...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Density, Specific Weight, Specific Gravity and Compressibility of Fluid
Specific weight represents the weight per unit volume and is calculated by multiplying...