Related Experiment Video
Updated: Feb 6, 2026

A Protocol for Constructing a Rat Wound Model of Type 1 Diabetes
Published on: February 17, 2023
Is insulin pump therapy effective in Type 1 diabetes?
1Department of Diabetes, King's College London, Guy's Hospital, London, UK.
Abstract:
There continues to be uncertainty about the effectiveness in Type 1 diabetes of insulin pump therapy (continuous subcutaneous insulin infusion, CSII) vs. multiple daily insulin injections (MDI). This narrative review discusses the reasons for this uncertainty, summarizes the current evidence base for CSII and suggests some future research needs. There are difficulties in interpreting trials of CSII because effectiveness varies widely due to factors such as differing baseline control, suboptimal use of best CSII practices, and psychological factors, for example, high external locus of control, non-adherence and lack of motivation. Many summary meta-analyses are also misleading because of poor trial selection (e.g. short duration, obsolete pumps, low baseline rate of hypoglycaemia) and reliance on mean effect size for decision-making. Both MDI and CSII can achieve strict glycaemic control without hypoglycaemia in some people with Type 1 diabetes, especially those who are motivated and have undergone structured diabetes education, and with high levels of ongoing input from healthcare professionals. CSII is particularly effective in those people with Type 1 diabetes who have not achieved target HbA1c levels without disabling hypoglycaemia using best attempts with MDI, and here there can be valuable and substantial improvement. Insulin pumps are safe, effective and accepted when used in newly diagnosed diabetes, particularly in children, where MDI may not be practicable. Future research needs include more studies on mortality associated with insulin pumps where registry data have suggested lower rates vs. MDI; and psychological strategies to improve non-adherence and suboptimal glycaemic outcomes on CSII.
Related Concept Videos
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes Mellitus: Type 2 and Gestational
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...

