Related Experiment Video
Updated: Feb 6, 2026

Development and Assessment of Intracellular Infection Models for Staphylococcus aureus
Published on: January 17, 2025
European external quality assessments for identification, molecular typing and characterization of Staphylococcus
Ariane Deplano1, Magali Dodémont1, Olivier Denis1
1Centre National de Référence S. aureus, Hôpital Erasme - Université Libre de Bruxelles (ULB), 808 Route de Lennik, Bruxelles, Belgium.
Objectives:
We present the results of two European external quality assessments (EQAs) conducted in 2014 and 2016 under the auspices of the Study Group on Staphylococci and Staphylococcal Infections of ESCMID. The objective was to assess the performance of participating centres in characterizing Staphylococcus aureus using their standard in-house phenotypic and genotypic protocols.
Methods:
A total of 11 well-characterized blindly coded S. aureus (n = 9), Staphylococcus argenteus (n = 1) and Staphylococcus capitis (n = 1) strains were distributed to participants for analysis. Species identification, MIC determination, antimicrobial susceptibility testing, antimicrobial resistance and toxin gene detection and molecular typing including spa typing, SCCmec typing and MLST were performed.
Results:
Thirteen laboratories from 12 European countries participated in one EQA or both EQAs. Despite considerable diversity in the methods employed, good concordance (90%-100%) with expected results was obtained. Discrepancies were observed for: (i) identification of the S. argenteus strain; (ii) phenotypic detection of low-level resistance to oxacillin in the mecC-positive strain; (iii) phenotypic detection of the inducible MLSB strain; and (iv) WGS-based detection of some resistance and toxin genes.
Conclusions:
Overall, good concordance (90%-100%) with expected results was observed. In some instances, the accurate detection of resistance and toxin genes from WGS data proved problematic, highlighting the need for validated and internationally agreed-on bioinformatics pipelines before such techniques are implemented routinely by microbiology laboratories. We strongly recommend all national reference laboratories and laboratories acting as referral centres to participate in such EQA initiatives.
Related Concept Videos
Work Done on a System by External Force
In the presence of a non-conservative opposing force, like friction, some part of the work done...
Molecular Models
Internal and External Forces
External and Internal Respiration
External Anatomy of the Kidney
The kidneys are located in the retroperitoneal space on either side of the vertebral column, protected posteriorly by the 11th and 12th ribs. The right kidney sits slightly lower than the left owing to the presence of the liver...
External Female Genitals

