Location of Reference Electrode Does Not Interfere on Electromyographic Parameters in the Domains of Time and
Rinaldo Roberto de Jesus Guirro1, Alcimar Barbosa Soares2, Amanda Caldeira Guirro2
1Department of Health Sience, Ribeirão Preto Medical School, University of São Paulo, Avenida Bandeirantes, 3900, Ribeirão Preto, São Paulo, CEP: 14049-900, Brazil.
Abstract:
There is currently little information on the positioning of reference electrode (RE). It is generally accepted that it must be positioned on electrically neutral tissues, such as tendons or bony prominences. The objective of this study is to analyze the characteristics of the electromyographic signal (EMG) for different positions of RE as well as at different levels of muscle contraction. Signals from the brachial biceps and triceps were recorded from 18 healthy women (BMI: 21.20 kg/m2 ± 1.72; mean age: 21.94 ± 1.98 years old) during 100 and 50% maximum flexion voluntary isometric contractions, as well as at rest. For each situation, the RE was randomly positioned in 4 different locations: a) homolateral acromion; b) homolateral brachial biceps; c) styloid process of the contralateral ulna; and d) lateral malleolus of the contralateral ankle. For statistical analysis, Shapiro-Wilk and Kruskal-Wallis tests were used, followed by Dunn's post-hoc test, at a significance level of 5% (p < 0.05). RMS, normalized RMS, PSD, median frequency and levels of energy at 60 Hz, 120 Hz and 180 Hz were assessed for the different sites of RE. The results show that the positioning of the RE on the four experimental locations did not change important features of the electromyographic signals in the time and frequency domains, for the three levels of isometric contractions studied. Such findings compel us to re-think the current trend regarding the RE position followed by the great majority of the researches in areas such as physical therapy.
Related Concept Videos
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...