Detection of pacific ciguatoxins using liquid chromatography coupled to either low or high resolution mass
Manoella Sibat1, Christine Herrenknecht2, Hélène Taiana Darius3
1Ifremer, Laboratoire Phycotoxines, Rue de l'Ile d'Yeu, 44311, Nantes, France.
Abstract:
Ciguatera Fish Poisoning (CFP) is primarily caused by consumption of tropical and sub-tropical fish contaminated by Ciguatoxins (CTXs). These lipid-soluble, polyether neurotoxins are produced by dinoflagellates in the genera Gambierdiscus and Fukuyoa. While there is no regulatory level in Europe for CTXs, the European Food Safety Authority (EFSA) adopted the United States guidance level of 0.01 μg P-CTX1B eq.kg-1 of fish. This limit is extremely low and requires significant improvement in the detection of CTXs. In this study, we compared analytical protocols based on liquid chromatography coupled to tandem low or high resolution mass spectrometry (LC-LRMS or HRMS) to find the best conditions for sensitivity and/or selectivity. Different approaches such as LC conditions, ion choice and acquisition modes, were evaluated to detect the Pacific-ciguatoxins (P-CTXs) on a triple quadrupole (API4000 Qtrap, Sciex) or a quadrupole time of flight (QTOF 6550, Agilent Technologies) spectrometer. Moreover, matrix effects were calculated using matrix-matched calibration solutions of P-CTX1B and P-CTX3C prepared in purified fish extract. Subsequently, the method performance was assessed on naturally contaminated samples of seafood and phytoplankton. With LRMS, the ammoniated adduct ion used as a precursor ion showed an advantage for selectivity through confirmatory transitions, without affecting signal-to-noise ratios, and hence limits of detection (LODs). As also reported by some studies in the literature, methanol-based mobile phase gave better selectivity and sensitivity for the detection of P-CTXs. While the LOD for P-CTX1B and P-CTX3C met the EFSA recommendation level when using LRMS, the findings suggested careful evaluation of instrumental parameters for determination of CTXs. LODs were significantly higher for HRMS, which currently results in the need for a significantly higher sample intake. Nevertheless, HRMS allowed for the identification of artefacts and may allow for improved confirmation of the identity of P-CTXs analogues. Consequently, LRMS and HRMS are considered complementary to ensure adequate quantitation and identification of P-CTXs.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
09:09Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
Related Concept Videos
High-Resolution Mass Spectrometry (HRMS)
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation