Related Experiment Video
Updated: Feb 6, 2026

Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Multi-stage SVM approach for cardiac arrhythmias detection in short single-lead ECG recorded by a wearable device
Radovan Smisek1,2,3, Jakub Hejc1,4, Marina Ronzhina1
1Faculty of Electrical Engineering and Communication, Department of Biomedical Engineering, Brno University of Technology, Technická 12, 616 00 Brno, Czechia.
Objective:
Use of wearable ECG devices for arrhythmia screening is limited due to poor signal quality, small number of leads and short records, leading to incorrect recognition of pathological events. This paper introduces a novel approach to classification (normal/'N', atrial fibrillation/'A', other/'O', and noisy/'P') of short single-lead ECGs recorded by wearable devices.
Approach:
Various rhythm and morphology features are derived from the separate beats ('local' features) as well as the entire ECGs ('global' features) to represent short-term events and general trends respectively. Various types of atrial and ventricular activity, heart beats and, finally, ECG records are then recognised by a multi-level approach combining a support vector machine (SVM), decision tree and threshold-based rules.
Main Results:
The proposed features are suitable for the recognition of 'A'. The method is robust due to the noise estimation involved. A combination of radial and linear SVMs ensures both high predictive performance and effective generalisation. Cost-sensitive learning, genetic algorithm feature selection and thresholding improve overall performance. The generalisation ability and reliability of this approach are high, as verified by cross-validation on a training set and by blind testing, with only a slight decrease of overall F1-measure, from 0.84 on training to 0.81 on the tested dataset. 'O' recognition seems to be the most difficult (test F1-measures: 0.90/'N', 0.81/'A' and 0.72/'O') due to high inter-patient variability and similarity with 'N'.
Significance:
These study results contribute to multidisciplinary areas, focusing on creation of robust and reliable cardiac monitoring systems in order to improve diagnosis, reduce unnecessary time-consuming expert ECG scoring and, consequently, ensure timely and effective treatment.
More Related Videos
Related Concept Videos
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Mechanism of Cardiac Arrhythmias
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Phase-lead and Phase-lag Controllers