Related Experiment Video
Updated: Feb 6, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
A retrospective study of SPECT/CT scans using SUV measurement of the normal pelvis with Tc-99m methylene
Ruifeng Wang1,2, Xiaoyi Duan1, Cong Shen1
1Department of Medical Image, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China.
Objective:
To perform quantitative measurement based on the standardized uptake value (SUV) of Tc-99m methylene diphosphonate (MDP) in the normal pelvis using a single-photon emission tomography (SPECT)/computed tomography (CT) scanner.
Material And Methods:
This retrospective study was performed on 31 patients with cancer undergoing bone SPECT/CT scans with 99mTc-MDP. SUVmax and SUVmean of the normal pelvis were calculated based on the body weight. SUVmax and SUVmean of the bilateral anterior superior iliac spine, posterior superior iliac spine, facies auricularis ossis ilii, ischial tuberosity, and sacrum were also calculated. Furthermore, the correlation of SUVmax and SUVmean of all parts of pelvis with weight, height, and CT was assessed.
Results:
The data for 31 patients (20 women and 11 men; mean age 58.97±9.12 years; age range 37-87 years) were collected. SUVmax and SUVmean changed from 1.65±0.40 to 3.8±1.0 and from 1.15±0.25 to 2.07±0.58, respectively. The coefficient of variation of SUVmax and SUVmean ranged from 0.22 to 0.31. SUVmax and SUVmean had no statistically significant difference between men and women. SUVmax and SUVmean also showed no significant correlation with weight and height. However, part of SUVmax and SUVmean showed a significant correlation with CT. In addition, SUVmax and SUVmean of the bilateral ischial tuberosity showed a significant correlation with CT values.
Conclusions:
Determination of the SUV value of the normal pelvis with 99m Tc-MDP SPECT/CT is feasible and highly reproducible. SUVs of the normal pelvis showed a relatively large variability. As a quantitative imaging biomarker, SUVs might require standardization with adequate reference data for the participant to minimize variability.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Veins of the Abdomen and Pelvis
The inferior vena cava is fed by numerous smaller veins. The lumbar veins, for instance, drain the posterior abdominal wall, emptying both directly into the inferior vena cava and into the...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Leaky Scanning
Normal Distribution