Related Experiment Video
Updated: Feb 6, 2026

Modifying the Bank Erosion Hazard Index BEHI Protocol for Rapid Assessment of Streambank Erosion in Northeastern Ohio
Published on: February 13, 2015
Translabial US: Preoperative Detection of Midurethral Sling Erosion in Stress Urinary Incontinence
Karoly A Viragh1, Seth A Cohen1, Luyao Shen1
1From the Department of Radiology, Columbia University, New York-Presbyterian/Lawrence Hospital, 622 W 168th St, PB-1-301, New York, NY 10032 (K.A.V.); Department of Surgery, Urology Division, City of Hope, Duarte, Calif (S.A.C.); Departments of Radiology (L.S., S.S.R.) and Surgery, Urology Division (S.R.), University of California, Los Angeles, Los Angeles, Calif; and Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, Calif (N.K.).
Abstract:
Purpose To evaluate the performance of translabial (TL) US in preoperative detection of sling erosion into pelvic organs with cystourethroscopic and surgical correlation. Materials and Methods The study cohort included women who underwent surgery at a subspecialty center (from 2008 to 2016) for suspected mesh complications in the setting of previous midurethral sling placement for stress urinary incontinence (from 1999 to 2012) with available preoperative TL US imaging. Clinical information, the finding of sling erosion identified intraoperatively and at cystourethroscopy, and blinded dual-reader radiologic analysis of the TL US studies for mesh location (intraluminal, mural, or extramural) relative to pelvic organs (bladder, urethra, vagina, or rectum) were evaluated. The diagnostic performance of TL US was correlated with the reference standard of surgical findings. The consensus of two radiologists was recorded, and interobserver agreement was evaluated with the κ statistic. Results Of the 124 women who were suspected of having sling erosion (mean age, 57.5 years ± 11.1 [standard deviation]), 15 women (12.1%) had sling erosion into the urethra or bladder at surgery. Sensitivity and specificity for erosion at TL US were 53% (95% confidence interval: 45%, 62%) and 100% (95% confidence interval: 97%, 100%), respectively, when erosion was defined as only intraluminal mesh products. Sensitivity and specificity for erosion at TL US were 93% (95% confidence interval: 89%, 98%) and 72% (95% confidence interval: 65%, 80%), respectively, when erosion was defined as visualizing either intraluminal or intramural mesh products. Interobserver agreement (κ value) was 0.95. Cystourethroscopy had 67% sensitivity and 100% specificity for sling erosion. Conclusion Preoperative translabial US can be used to detect sling erosion into the lower urinary tract, with sensitivity up to 93% and specificity up to 100%. © RSNA, 2018 Online supplemental material is available for this article. See also the editorial by Benson and Phillips in this issue.
Related Concept Videos
Introduction to Urinary System
The kidneys are bean-shaped organs located in the retroperitoneal space, on either side of the vertebral column, between the T12 and L3 vertebrae. They are partially protected by the rib cage and surrounded by perirenal fat, which provides cushioning. They are responsible for urine formation and play critical roles in regulating blood pressure, electrolyte levels, and hormone production. The ureters...
Urinary Bladder
In males, the bladder is situated in front of the rectum, while in females, it is positioned anterior to the vagina and uterus. The bladder floor contains an inverted triangular area called the trigone, defined by the two ureteric...
Disorders of the Urinary System
Urinary tract infections (UTIs) are one of the most common urinary system disorders. They are caused by bacteria that enter the urethra and can spread to the bladder resulting in cystitis. Pyelonephritis is the result of a UTI that has ascended to the level of the...
Responses to Salt Stress
Urinary Tract Calculi I: Introduction
Responses to Heat and Cold Stress

