Related Experiment Video
Updated: Feb 6, 2026

How to Create and Use Binocular Rivalry
Published on: November 10, 2010
Effects of astigmatic defocus on binocular contrast sensitivity
Yumi Hasegawa1, Takahiro Hiraoka1, Shinichiro Nakano2
1Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan.
Purpose:
To determine the effects of astigmatism on contrast sensitivity (CS).
Methods:
Eighteen normal volunteers (30.5 ± 6.0 [mean ± SD] years) were recruited. After correcting each refractive error by spectacles, against-the-rule (ATR) or with-the-rule (WTR) astigmatism of +1.00, +2.00 and +3.00 D was intentionally produced in both eyes, and then binocular CS was measured. The cylindrical addition of different powers (+1.00-+3.00 D) was compensated with spherical lenses so that the spherical equivalent refraction became zero in each eye. Subsequently, the above cylindrical addition was monocularly induced, and binocular CS was measured again. The relation between CS and astigmatic power, axis, and monocular or binocular astigmatism was investigated.
Results:
With binocular ATR and WTR astigmatism, increases in astigmatic power significantly correlated with decreases in the area under the log contrast sensitivity function (AULCSF). With monocular astigmatic defocus, astigmatic power addition did not affect AULCSF. With binocular astigmatic defocus of high-power (+2.00 and +3.00 D), ATR astigmatism deteriorated AULCSF more than WTR astigmatism. In a comparison between binocular and monocular astigmatic defocus, CS was significantly worse with binocular astigmatic defocus than with monocular astigmatic defocus at higher spatial frequencies regardless of astigmatic power.
Conclusions:
Binocular astigmatic defocus deteriorates CS depending on the amount of astigmatic power. ATR astigmatism reduces CS more than WTR astigmatism dose. In addition, binocular astigmatic defocus affects CS more severely than monocular astigmatic defocus especially at high spatial frequencies.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Biological Effects of Radiation
Framing Effects
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...