Background:
Transcatheter aortic valve replacement (TAVR) has been performed for many elderly patients with severe aortic stenosis (AS). The SAPIEN 3 is one of the latest balloon-expandable prosthesis. This study aimed to investigate the early clinical outcomes after TAVR using the SAPIEN 3 in nonagenarians.
Methods:
A total of 97 consecutive patients underwent TAVR for severe AS between December 2015 and December 2016. Of these, 85 consecutive patients who underwent TAVR using the SAPIEN 3 were included. According to the age, patients were classified into age ≥ 90 years group (17 patients) or age < 90 years group (68 patients). The clinical outcomes including all-cause mortality and composite endpoint of early safety at 30 days were evaluated.
Results:
The Society of Thoracic Surgeons score in age ≥ 90 years group was higher than age < 90 years group (12.3 ± 6.1% vs. 8.5 ± 5.1%, P < 0.01). There was no significant difference in 30-day mortality between the two groups. However, the life-threatening bleeding and major vascular complications in age ≥ 90 years group were greater than age < 90 years group (11.8% vs. 1.5%, P = 0.04 and 11.8% vs. 1.5%, P = 0.04, respectively). The composite endpoint of early safety at 30 days was similar between the two groups. Multivariate logistic regression analysis showed that prior myocardial infarction was an independent predictor of the composite endpoint of early safety (odds ratio: 4.76, 95% confidence interval: 1.02-22.21, P = 0.047).
Conclusions:
The early mortality and safety after TAVR using the SAPIEN 3 in nonagenarians were similar and acceptable despite of higher operative risk.
Related Concept Videos
Survey Safety
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...