Related Experiment Video
Updated: Feb 6, 2026

The Measurement of Unsteady Surface Pressure Using a Remote Microphone Probe
Published on: December 3, 2016
Cavitating flow-induced unsteady pressure pulsations in a low specific speed centrifugal pump
Ning Zhang1, Bo Gao1, Zhong Li1
1School of Energy and Power Engineering, Jiangsu University, Zhenjiang 212013, People's Republic of China.
Abstract:
With the development of cavitation, the high-energy pressure wave from a cavitation bubble collapsing is detrimental to the stable operation of centrifugal pumps. The present paper concentrates on pressure pulsations under cavitation conditions, and pressure amplitudes at the blade-passing frequency (fBPF) and RMS values in the 0-500 Hz frequency band are combined to investigate cavitation-induced pressure pulsations. The results show that components at fBPF always dominate the pressure spectrum even at the full cavitation stage. For points P1-P7 on the volute side wall, with a decreasing cavitation number, the pressure energy first remains unchanged and then it rises rapidly after the critical point. For point In1 in a volute suction pipe located close to the cavitation region, the pressure energy changes slightly at high cavitation numbers; then for a particular cavitation number range, the pressure energy decreases, and finally increases again. For different flow rates, the pressure energy at the critical point is much lower than the initial amplitude at the non-cavitation condition for In1. This demonstrates that the cavitation cloud in the typical stage is partially compressible, and the emitted pressure wave from a collapsing cavitation bubble is absorbed and attenuated significantly. Finally, this leads to the pressure energy decreasing rapidly for the measuring point In1 near the cavitation region.
Related Concept Videos
Velocity and Acceleration in Steady and Unsteady Flow
The acceleration can be generalized to any point in the flow, and expressed as components along three perpendicular directions, representing changes in velocity over...
Centrifugation
Heat Flow and Specific Heat
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Centrifugal Force