Related Experiment Video
Updated: Feb 6, 2026

Rejection of Fluorescence Background in Resonance and Spontaneous Raman Microspectroscopy
Published on: May 18, 2011
Fitting an Optical Fiber Background with a Weighted Savitzky-Golay Smoothing Filter for Raman Spectroscopy
Jie Huang1, Tielin Shi1, Bo Gong1
11 12443 State Key Lab of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan, China.
Abstract:
The Raman background arising from optical fiber materials poses a critical problem for fiber optic surface-enhanced Raman spectroscopy (SERS). A novel filter is developed to fit the optical fiber background from the measured SERS spectrum of the target sample. The general model of the filter is built by incorporating a weighted term of matching the similarity between the estimated background spectrum and the measured background spectrum into the classic Savitzky-Golay (SG) smoothing filter model. Through respectively selecting Euclidean cosine coefficient (ECos) and Pearson correlation coefficient (PCor) as the similarity index, two different models of the weighted SG smoothing filter are derived and named as SG-ECos and SG-PCor accordingly. Furthermore, the algorithm is presented, implemented, successfully applied to experimentally measured SERS spectra of rhodamine 6G and crystal violet, and validated with mathematically simulated Raman spectra. Experimental and simulation results show that the SG-ECos filter is effective, fast, flexible, and of certain anti-noise capability in background fitting. It is suggested that the proposed filter may be also applicable for other Raman spectra measurements to remove spectral contaminants originated from sampling substrates such as glass slides.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Induced-fit Model
Enzymes exhibit substrate specificity, meaning that they can only bind to certain substrates. This is mainly determined by the shape and chemical...
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Inclusive Fitness
Goodness-of-Fit Test

