Related Experiment Video
Updated: Feb 6, 2026

Graphene Coatings for Biomedical Implants
Published on: March 1, 2013
Strong Adhesion of Graphene Oxide Coating on Polymer Separation Membranes
Ruirui Hu1, Yijia He1, Meirong Huang1
1State Key Lab of New Ceramics and Fine Processing, School of Materials Science and Engineering , Tsinghua University , C213 Yifu Technology and Science Building , Beijing 100084 , China.
Abstract:
Graphene oxide (GO) has been demonstrated as the most promising candidate for surface modification of polymer separation membranes for durable filtration applications. However, the adhesion between GO coating and polymer substrate, as the most essential issue for reliable applications, has been little explored. Herein, we developed a facile high-pressure assisted deposition method to physically anchor GO sheets on microfiltration (MF) and reverse osmosis (RO) membranes, and established a tape test procedure for assessing the adhesion of GO coating to polymer substrates based on the ASTM D3359. Through regulating the GO sources and coating process, we demonstrated that the adhesion depends sensitively on the GO flake size and deposition pressure, whereas the adhesion level dramatically improved from 0B to 5B, with decrease in the lateral size of GO and increase in the coating deposition pressure. The strong GO coatings showed evidently higher water flux than that of weak counterparts. The underlying mechanism was further analyzed and verified. Nanosize of GO and high deposition pressure favor the formation of the conformal morphologies of GO coatings on both MF and RO membranes, which allow strong interfacial van der Waals interaction because of the large contact areas and result in the strong GO coatings on membranes. These results potentially open up a versatile pathway to develop the strong graphene-based coatings on separation membranes.
More Related Videos
08:57Scalable Syntheses of Graphene Oxide and Reduced Graphene Oxide using Cascade Design Oxidation and Highly Basic Reduction Reactions
Published on: July 3, 2025
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
Related Concept Videos
Strong Acid and Base Solutions
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Polymers
Polymers
Titration of a Strong Acid with a Strong Base
Adhesion
Capillary action is a result of water’s adhesive tendencies. When a narrow...